mlsanityData to 7 Oct 2026

DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising

arXiv 2603.07759 ↗First posted 8 Mar 2026cs.CV cs.AIcited by 0

On the map: Diffusion models → Medical imaging and segmentation

Abstract (arXiv)

Rb-82 dynamic cardiac PET imaging is widely used for the clinical diagnosis of coronary artery disease (CAD), but its short half-life results in high noise levels that degrade dynamic frame quality and parametric imaging. The lack of paired clean-noisy training data, rapid tracer kinetics, and frame-dependent noise variations further limit the effectiveness of existing deep learning denoising methods. We propose DECADE (A Temporally-Consistent Unsupervised Diffusion model for Enhanced Rb-82 CArdiac PET DEnoising), an unsupervised diffusion framework that generalizes across early- to late-phase dynamic frames. DECADE incorporates temporal consistency during both training and iterative sampling, using noisy frames as guidance to preserve quantitative accuracy. The method was trained and evaluated on datasets acquired from Siemens Vision 450 and Siemens Biograph Vision Quadra scanners. On the Vision 450 dataset, DECADE consistently produced high-quality dynamic and parametric images with reduced noise while preserving myocardial blood flow (MBF) and myocardial flow reserve (MFR). On the Quadra dataset, using 15%-count images as input and full-count images as reference, DECADE outperformed UNet-based and other diffusion models in image quality and K1/MBF quantification. The proposed framework enables effective unsupervised denoising of Rb-82 dynamic cardiac PET without paired training data, supporting clearer visualization while maintaining quantitative integrity.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. Builds on 25 of its 51 references that are in the map. First posted on arXiv 8 Mar 2026.

Builds on

25 of 51 references.

Closest ancestors · 6

Same direction, newest first

  1. 2025Fed-NDIF: A Noise-Embedded Federated Diffusion Model For Low-Count Whole-Body PET Denoising20 Mar
  2. 20242.5D Multi-view Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-count PET Reconstruction with CT-less Attenuation Correction12 Jun
  3. 2024Cascaded Multi-path Shortcut Diffusion Model for Medical Image Translation6 Apr
  4. 2024Anatomically-Controllable Medical Image Generation with Segmentation-Guided Diffusion Models7 Feb
  5. 2022MedSegDiff: Medical Image Segmentation with Diffusion Probabilistic Model1 Nov
  6. 2022PET image denoising based on denoising diffusion probabilistic models13 Sep

Other references · 19

  1. 2020Denoising Diffusion Probabilistic Modelscited by 20,851
  2. 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,604
  3. 2020Denoising Diffusion Implicit Modelscited by 9,655
  4. 2021Diffusion Models Beat GANs on Image Synthesiscited by 8,185
  5. 2023Adding Conditional Control to Text-to-Image Diffusion Modelscited by 5,466
  6. 2022Diffusion Posterior Sampling for General Noisy Inverse Problemscited by 1,375
  7. 2021Palette: Image-to-Image Diffusion Modelscited by 1,296
  8. 2017Deep Image Priorcited by 1,097
  9. 2022TotalSegmentator: robust segmentation of 104 anatomical structures in CT imagescited by 597
  10. 2018Noise2Void - Learning Denoising from Single Noisy Imagescited by 359
  11. 2022Cold Diffusion: Inverting Arbitrary Image Transforms Without Noisecited by 275
  12. 2022BBDM: Image-to-image Translation with Brownian Bridge Diffusion Modelscited by 222
7 more
  1. 2022Spach Transformer: Spatial and Channel-wise Transformer Based on Local and Global Self-attentions for PET Image Denoisingcited by 19
  2. 2017200x Low-dose PET Reconstruction using Deep Learningcited by 18
  3. 2021Anatomical-Guided Attention Enhances Unsupervised PET Image Denoising Performancecited by 10
  4. 2024TAI-GAN: A Temporally and Anatomically Informed Generative Adversarial Network for early-to-late frame conversion in dynamic cardiac PET inter-frame motion correctioncited by 2
  5. 2024LeqMod: Adaptable Lesion-Quantification-Consistent Modulation for Deep Learning Low-Count PET Image Denoisingcited by 2
  6. 2024Noise-aware Dynamic Image Denoising and Positron Range Correction for Rubidium-82 Cardiac PET Imaging via Self-supervisioncited by 1
  7. 2025Anatomically and Metabolically Informed Diffusion for Unified Denoising and Segmentation in Low-Count PET Imagingcited by 1

Built on by

Not cited yet.

Similar, not cited

Close in wording, no citation either way

  1. 2026Less Is More: Training-Free Acceleration Framework of 3D Diffusion Models for Low-Count PET Denoising via Global-Local Trajectory Reduction
  2. 2024Dose-aware Diffusion Model for 3D PET Image Denoising: Multi-institutional Validation with Reader Study and Real Low-dose Data
  3. 2024Adaptive Whole-Body PET Image Denoising Using 3D Diffusion Models with ControlNet
  4. 2026Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy
  5. 2025Supervised Diffusion-Model-Based PET Image Reconstruction
  6. 2026MAP-Diff: Multi-Anchor Guided Diffusion for Progressive 3D Whole-Body Low-Dose PET Denoising
  7. 20263D Wavelet-Based Structural Priors for Controlled Diffusion in Whole-Body Low-Dose PET Denoising
  8. 2025PET Image Denoising via Text-Guided Diffusion: Integrating Anatomical Priors through Text Prompts