mlsanityData to 7 Oct 2026

Anatomical-Guided Attention Enhances Unsupervised PET Image Denoising Performance

arXiv 2109.00802 ↗First posted 2 Sep 2021physics.med-ph cs.CV cs.LGcited by 10

Not on the map. Why?

Abstract (arXiv)

Although supervised convolutional neural networks (CNNs) often outperform conventional alternatives for denoising positron emission tomography (PET) images, they require many low- and high-quality reference PET image pairs. Herein, we propose an unsupervised 3D PET image denoising method based on an anatomical information-guided attention mechanism. The proposed magnetic resonance-guided deep decoder (MR-GDD) utilizes the spatial details and semantic features of MR-guidance image more effectively by introducing encoder-decoder and deep decoder subnetworks. Moreover, the specific shapes and patterns of the guidance image do not affect the denoised PET image, because the guidance image is input to the network through an attention gate. In a Monte Carlo simulation of [18F]fluoro-2-deoxy-D-glucose (FDG), the proposed method achieved the highest peak signal-to-noise ratio and structural similarity (27.92 ± 0.44 dB/0.886 ± 0.007), as compared with Gaussian filtering (26.68 ± 0.10 dB/0.807 ± 0.004), image guided filtering (27.40 ± 0.11 dB/0.849 ± 0.003), deep image prior (DIP) (24.22 ± 0.43 dB/0.737 ± 0.017), and MR-DIP (27.65 ± 0.42 dB/0.879 ± 0.007). Furthermore, we experimentally visualized the behavior of the optimization process, which is often unknown in unsupervised CNN-based restoration problems. For preclinical (using [18F]FDG and [11C]raclopride) and clinical (using [18F]florbetapir) studies, the proposed method demonstrates state-of-the-art denoising performance while retaining spatial resolution and quantitative accuracy, despite using a common network architecture for various noisy PET images with 1/10th of the full counts. These results suggest that the proposed MR-GDD can reduce PET scan times and PET tracer doses considerably without impacting patients.

Key facts. Cited by 10 papers in the map (data through 7 Oct 2026). Builds on 9 of its 59 references that are in the map. First posted on arXiv 2 Sep 2021.

Builds on

9 of 59 references.

References · 9

  1. 20163D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotationcited by 1,471
  2. 2017A Survey on Deep Learning in Medical Image Analysiscited by 1,182
  3. 2017Deep Image Priorcited by 1,097
  4. 2018Noise2Noise: Learning Image Restoration without Clean Datacited by 526
  5. 2018Attention Gated Networks: Learning to Leverage Salient Regions in Medical Imagescited by 271
  6. 2018Attention Branch Network: Learning of Attention Mechanism for Visual Explanationcited by 108
  7. 2018DeepPET: A deep encoder-decoder network for directly solving the PET reconstruction inverse problemcited by 40
  8. 2020Guided Deep Decoder: Unsupervised Image Pair Fusioncited by 20
  9. 2019Full-count PET Recovery from Low-count Image Using a Dilated Convolutional Neural Networkcited by 11

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2022: 3; 2023: 2; 2024: 2; 2025: 2; 2026: 1.

10 papers.