mlsanityData to 7 Oct 2026

A study on the adequacy of common IQA measures for medical images

arXiv 2405.19224 ↗First posted 29 May 2024eess.IV cs.CVcited by 10

Not on the map. Why?

Abstract (arXiv)

Image quality assessment (IQA) is standard practice in the development stage of novel machine learning algorithms that operate on images. The most commonly used IQA measures have been developed and tested for natural images, but not in the medical setting. Reported inconsistencies arising in medical images are not surprising, as they have different properties than natural images. In this study, we test the applicability of common IQA measures for medical image data by comparing their assessment to manually rated chest X-ray (5 experts) and photoacoustic image data (2 experts). Moreover, we include supplementary studies on grayscale natural images and accelerated brain MRI data. The results of all experiments show a similar outcome in line with previous findings for medical images: PSNR and SSIM in the default setting are in the lower range of the result list and HaarPSI outperforms the other tested measures in the overall performance. Also among the top performers in our experiments are the full reference measures FSIM, LPIPS and MS-SSIM. Generally, the results on natural images yield considerably higher correlations, suggesting that additional employment of tailored IQA measures for medical imaging algorithms is needed.

Key facts. Cited by 10 papers in the map (data through 7 Oct 2026). Builds on 12 of its 35 references that are in the map. First posted on arXiv 29 May 2024.

Builds on

12 of 35 references.

References · 12

  1. 2018The Unreasonable Effectiveness of Deep Features as a Perceptual Metriccited by 11,029
  2. 2020Image Quality Assessment: Unifying Structure and Texture Similaritycited by 792
  3. 2018fastMRI: An Open Dataset and Benchmarks for Accelerated MRIcited by 464
  4. 2019From Patches to Pictures (PaQ-2-PiQ): Mapping the Perceptual Space of Picture Qualitycited by 221
  5. 2020End-to-End Variational Networks for Accelerated MRI Reconstructioncited by 201
  6. 2013Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Indexcited by 193
  7. 2016A Haar Wavelet-Based Perceptual Similarity Index for Image Quality Assessmentcited by 57
  8. 2016Mean Deviation Similarity Index: Efficient and Reliable Full-Reference Image Quality Evaluatorcited by 32
  9. 2021A Hitchhiker's Guide to Structural Similaritycited by 16
  10. 2020XPDNet for MRI Reconstruction: an application to the 2020 fastMRI challengecited by 13
  11. 2023Moving beyond simulation: data-driven quantitative photoacoustic imaging using tissue-mimicking phantomscited by 10
  12. 2021Artifact- and content-specific quality assessment for MRI with image rulerscited by 8

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2024: 2; 2025: 6; 2026: 2.

10 papers.