mlsanityData to 14 Oct 2026

Parameter choices in HaarPSI for IQA with medical images

arXiv 2410.24098 ↗First posted 31 Oct 2024eess.IV cs.CVcited by 2

Not on the map. Why?

Abstract (arXiv)

When developing machine learning models, image quality assessment (IQA) measures are a crucial component for the evaluation of obtained output images. However, commonly used full-reference IQA (FR-IQA) measures have been primarily developed and optimized for natural images. In many specialized settings, such as medical images, this poses an often overlooked problem regarding suitability. In previous studies, the FR-IQA measure HaarPSI showed promising behavior regarding generalizability. The measure is based on Haar wavelet representations and the framework allows optimization of two parameters. So far, these parameters have been aligned for natural images. Here, we optimize these parameters for two medical image data sets, a photoacoustic and a chest X-ray data set, with IQA expert ratings. We observe that they lead to similar parameter values, different to the natural image data, and are more sensitive to parameter changes. We denote the novel optimized setting as HaarPSIMED, which improves the performance of the employed medical images significantly (p<0.05). Additionally, we include an independent CT test data set that illustrates the generalizability of HaarPSIMED, as well as visual examples that qualitatively demonstrate the improvement. The results suggest that adapting common IQA measures within their frameworks for medical images can provide a valuable, generalizable addition to employment of more specific task-based measures.

Key facts. Cited by 2 papers in the map (data through 14 Oct 2026). Builds on 8 of its 27 references that are in the map. First posted on arXiv 31 Oct 2024.

Builds on

8 of 27 references.

References · 8

  1. 2018The Unreasonable Effectiveness of Deep Features as a Perceptual Metriccited by 11,177
  2. 2020Image Quality Assessment: Unifying Structure and Texture Similaritycited by 811
  3. 2013Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Indexcited by 195
  4. 2016A Haar Wavelet-Based Perceptual Similarity Index for Image Quality Assessmentcited by 57
  5. 2016Mean Deviation Similarity Index: Efficient and Reliable Full-Reference Image Quality Evaluatorcited by 32
  6. 2024A study of why we need to reassess full reference image quality assessment with medical imagescited by 17
  7. 2023Moving beyond simulation: data-driven quantitative photoacoustic imaging using tissue-mimicking phantomscited by 10
  8. 2024A study on the adequacy of common IQA measures for medical imagescited by 10

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2025: 1; 2026: 1.

2 papers.