mlsanityData to 14 Oct 2026

Artifact- and content-specific quality assessment for MRI with image rulers

arXiv 2111.03780 ↗First posted 6 Nov 2021eess.IV cs.AI cs.CVcited by 8

Not on the map. Why?

Abstract (arXiv)

In clinical practice MR images are often first seen by radiologists long after the scan. If image quality is inadequate either patients have to return for an additional scan, or a suboptimal interpretation is rendered. An automatic image quality assessment (IQA) would enable real-time remediation. Existing IQA works for MRI give only a general quality score, agnostic to the cause of and solution to low-quality scans. Furthermore, radiologists' image quality requirements vary with the scan type and diagnostic task. Therefore, the same score may have different implications for different scans. We propose a framework with multi-task CNN model trained with calibrated labels and inferenced with image rulers. Labels calibrated by human inputs follow a well-defined and efficient labeling task. Image rulers address varying quality standards and provide a concrete way of interpreting raw scores from the CNN. The model supports assessments of two of the most common artifacts in MRI: noise and motion. It achieves accuracies of around 90%, 6% better than the best previous method examined, and 3% better than human experts on noise assessment. Our experiments show that label calibration, image rulers, and multi-task training improve the model's performance and generalizability.

Key facts. Cited by 8 papers in the map (data through 14 Oct 2026). Builds on 16 of its 53 references that are in the map. First posted on arXiv 6 Nov 2021.

Builds on

16 of 53 references.

References · 16

  1. 2014Adam: A Method for Stochastic Optimizationcited by 37,240
  2. 2015Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shiftcited by 7,005
  3. 2016Layer Normalizationcited by 5,669
  4. 2017Image reconstruction by domain transform manifold learningcited by 232
  5. 2016Deep Neural Networks for No-Reference and Full-Reference Image Quality Assessmentcited by 225
  6. 2019From Patches to Pictures (PaQ-2-PiQ): Mapping the Perceptual Space of Picture Qualitycited by 223
  7. 2015Density Modeling of Images using a Generalized Normalization Transformationcited by 127
  8. 2019Deep Learning Methods for Parallel Magnetic Resonance Image Reconstructioncited by 81
  9. 2019dipIQ: Blind Image Quality Assessment by Learning-to-Rank Discriminable Image Pairscited by 73
  10. 2019A deep learning framework for quality assessment and restoration in video endoscopycited by 24
  11. 2018Automatic CNN-based detection of cardiac MR motion artefacts using k-space data augmentation and curriculum learningcited by 22
  12. 2019Wasserstein GANs for MR Imaging: from Paired to Unpaired Trainingcited by 14
4 more
  1. 2018A Machine-learning framework for automatic reference-free quality assessment in MRIcited by 10
  2. 2017Blind estimation of white Gaussian noise variance in highly textured imagescited by 6
  3. 2020Rank-smoothed Pairwise Learning In Perceptual Quality Assessmentcited by 5
  4. 2019Real-Time Quality Assessment of Pediatric MRI via Semi-Supervised Deep Nonlocal Residual Neural Networkscited by 4

Built on by

Cited by year

Citing papers per year: 2022: 2; 2023: 1; 2024: 3; 2025: 2.

8 papers.