mlsanityData to 14 Oct 2026

A study of why we need to reassess full reference image quality assessment with medical images

arXiv 2405.19097 ↗First posted 29 May 2024eess.IV cs.CVcited by 17

Not on the map. Why?

Abstract (arXiv)

Image quality assessment (IQA) is indispensable in clinical practice to ensure high standards, as well as in the development stage of machine learning algorithms that operate on medical images. The popular full reference (FR) IQA measures PSNR and SSIM are known and tested for working successfully in many natural imaging tasks, but discrepancies in medical scenarios have been reported in the literature, highlighting the gap between development and actual clinical application. Such inconsistencies are not surprising, as medical images have very different properties than natural images, and PSNR and SSIM have neither been targeted nor properly tested for medical images. This may cause unforeseen problems in clinical applications due to wrong judgment of novel methods. This paper provides a structured and comprehensive overview of examples where PSNR and SSIM prove to be unsuitable for the assessment of novel algorithms using different kinds of medical images, including real-world MRI, CT, OCT, X-Ray, digital pathology and photoacoustic imaging data. Therefore, improvement is urgently needed in particular in this era of AI to increase reliability and explainability in machine learning for medical imaging and beyond. Lastly, we will provide ideas for future research as well as suggesting guidelines for the usage of FR-IQA measures applied to medical images.

Key facts. Cited by 17 papers in the map (data through 14 Oct 2026). Builds on 23 of its 115 references that are in the map. First posted on arXiv 29 May 2024.

Builds on

23 of 115 references.

References · 23

  1. 2018The Unreasonable Effectiveness of Deep Features as a Perceptual Metriccited by 11,177
  2. 2018fastMRI: An Open Dataset and Benchmarks for Accelerated MRIcited by 470
  3. 2016Deep Convolutional Neural Network for Inverse Problems in Imagingcited by 433
  4. 2017Learned Primal-dual Reconstructioncited by 251
  5. 2020End-to-End Variational Networks for Accelerated MRI Reconstructioncited by 202
  6. 2022Metrics reloaded: Recommendations for image analysis validationcited by 195
  7. 2021GANs for Medical Image Synthesis: An Empirical Studycited by 65
  8. 2020Advancing machine learning for MR image reconstruction with an open competition: Overview of the 2019 fastMRI challengecited by 59
  9. 2016A Haar Wavelet-Based Perceptual Similarity Index for Image Quality Assessmentcited by 57
  10. 2020Learned convex regularizers for inverse problemscited by 55
  11. 2023Self-Supervised MRI Reconstruction with Unrolled Diffusion Modelscited by 38
  12. 2020Deep learning for biomedical photoacoustic imaging: A reviewcited by 21
11 more
  1. 2018Task adapted reconstruction for inverse problemscited by 16
  2. 2021A Hitchhiker's Guide to Structural Similaritycited by 16
  3. 2020XPDNet for MRI Reconstruction: an application to the 2020 fastMRI challengecited by 13
  4. 2023Moving beyond simulation: data-driven quantitative photoacoustic imaging using tissue-mimicking phantomscited by 10
  5. 2023FastMRI Prostate: A Publicly Available, Biparametric MRI Dataset to Advance Machine Learning for Prostate Cancer Imagingcited by 9
  6. 2021Artifact- and content-specific quality assessment for MRI with image rulerscited by 8
  7. 2019Estimation of blood oxygenation with learned spectral decoloring for quantitative photoacoustic imaging (LSD-qPAI)cited by 7
  8. 2019High-fidelity, accelerated whole-brain submillimeter in-vivo diffusion MRI using gSlider-Spherical Ridgelets (gSlider-SR)cited by 5
  9. 2020Self-Supervised Training For Low Dose CT Reconstructioncited by 4
  10. 2021AAPM DL-Sparse-View CT Challenge Submission Report: Designing an Iterative Network for Fanbeam-CT with Unknown Geometrycited by 3
  11. 2019On the reconstruction accuracy of multi-coil MRI with orthogonal projectionscited by 2

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2024: 2; 2025: 8; 2026: 7.

17 papers.

Sort:

By area:

  1. 2025Benchmarking Self-Supervised Learning Methods for Accelerated MRI Reconstructioncited by 4
  2. 2024Parameter choices in HaarPSI for IQA with medical imagescited by 2
  3. 2024Learned denoising with simulated and experimental low-dose CT datacited by 1
  4. 2025Pathology-Guided Virtual Staining Metric for Evaluation and Trainingcited by 1
  5. 2026Cross Modality Image Translation In Medical Imaging Using Generative Frameworkscited by 1
  6. 2026Prior-Guided Implicit Neural Representations for Single-Subject Diffusion MRI Super-Resolutioncited by 1
  7. 2025PhotIQA: A photoacoustic image data set with image quality ratingscited by 0
  8. 2025PPORLD-EDNetLDCT: A Proximal Policy Optimization-Based Reinforcement Learning Framework for Adaptive Low-Dose CT Denoisingcited by 0
  9. 2025Generative deep learning for foundational video translation in ultrasoundcited by 0
  10. 2025Building Trust in Virtual Immunohistochemistry: Automated Assessment of Image Qualitycited by 0
  11. 2025Task-Adaptive Low-Dose CT Reconstructioncited by 0
  12. 2025Prompt-Conditioned FiLM and Multi-Scale Fusion on MedSigLIP for Low-Dose CT Quality Assessmentcited by 0
5 more
  1. 2026No-reference based automatic parameter optimization for iterative reconstruction using a novel search space aware crow search algorithmcited by 0
  2. 2026Deep Image Prior for photoacoustic tomography can mitigate limited-view artifactscited by 0
  3. 2026HAPS: Rethinking Image Similarity for Virtual Stainingcited by 0
  4. 2026One-Step Is Optimal: Unconditional Rectified Flows are Noise2Noise Denoisers, and Multi-Step Integration Provably Hurts---A Benchmark and Task-Based Detectability Study on Low-Dose CTcited by 0
  5. 2026M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Modelscited by 0