Blind CT Image Quality Assessment Using DDPM-derived Content and Transformer-based Evaluator
Not on the map. Why?
Abstract (arXiv)
Lowering radiation dose per view and utilizing sparse views per scan are two common CT scan modes, albeit often leading to distorted images characterized by noise and streak artifacts. Blind image quality assessment (BIQA) strives to evaluate perceptual quality in alignment with what radiologists perceive, which plays an important role in advancing low-dose CT reconstruction techniques. An intriguing direction involves developing BIQA methods that mimic the operational characteristic of the human visual system (HVS). The internal generative mechanism (IGM) theory reveals that the HVS actively deduces primary content to enhance comprehension. In this study, we introduce an innovative BIQA metric that emulates the active inference process of IGM. Initially, an active inference module, implemented as a denoising diffusion probabilistic model (DDPM), is constructed to anticipate the primary content. Then, the dissimilarity map is derived by assessing the interrelation between the distorted image and its primary content. Subsequently, the distorted image and dissimilarity map are combined into a multi-channel image, which is inputted into a transformer-based image quality evaluator. Remarkably, by exclusively utilizing this transformer-based quality evaluator, we won the second place in the MICCAI 2023 low-dose computed tomography perceptual image quality assessment grand challenge. Leveraging the DDPM-derived primary content, our approach further improves the performance on the challenge dataset.
Key facts. Cited by 2 papers in the map (data through 14 Oct 2026). Builds on 23 of its 68 references that are in the map. First posted on arXiv 4 Oct 2023.
Builds on
23 of 68 references.
References · 23
- 2020An Image is Worth 16x16 Words: Transformers for Image Recognition at Scalecited by 30,186
- 2020Denoising Diffusion Probabilistic Modelscited by 21,076
- 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,713
- 2021High-Resolution Image Synthesis with Latent Diffusion Modelscited by 18,863
- 2020Score-Based Generative Modeling through Stochastic Differential Equationscited by 9,122
- 2021Diffusion Models Beat GANs on Image Synthesiscited by 8,255
- 2021Image Super-Resolution via Iterative Refinementcited by 1,511
- 2021MUSIQ: Multi-scale Image Quality Transformercited by 1,081
- 2022MANIQA: Multi-dimension Attention Network for No-Reference Image Quality Assessmentcited by 522
- 2016Deep Convolutional Neural Network for Inverse Problems in Imagingcited by 433
- 2019Blind Image Quality Assessment Using A Deep Bilinear Convolutional Neural Networkcited by 302
- 2017Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)cited by 224
11 more
- 2021No-Reference Image Quality Assessment via Transformers, Relative Ranking, and Self-Consistencycited by 166
- 2017Low Dose CT Image Denoising Using a Generative Adversarial Network with Wasserstein Distance and Perceptual Losscited by 162
- 2017Framing U-Net via Deep Convolutional Framelets: Application to Sparse-view CTcited by 88
- 2020Transformer for Image Quality Assessmentcited by 76
- 2018Hallucinated-IQA: No-Reference Image Quality Assessment via Adversarial Learningcited by 49
- 20183D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning from a 2D Trained Networkcited by 47
- 2022CTformer: Convolution-free Token2Token Dilated Vision Transformer for Low-dose CT Denoisingcited by 46
- 2022NTIRE 2022 Challenge on Perceptual Image Quality Assessmentcited by 41
- 2020MetaInv-Net: Meta Inversion Network for Sparse View CT Image Reconstructioncited by 23
- 2022MSTRIQ: No Reference Image Quality Assessment Based on Swin Transformer with Multi-Stage Fusioncited by 10
- 2022Conformer and Blind Noisy Students for Improved Image Quality Assessmentcited by 5
Built on by
Citing papers per year: 2026: 2.
2 papers.
Similar, not cited
Close in wording, no citation either way
- 2024Feature Denoising Diffusion Model for Blind Image Quality Assessment
- 2024ExIQA: Explainable Image Quality Assessment Using Distortion Attributes
- 2026DeVAR: Low-Dose CT Denoising via Visual Autoregressive Modeling
- 2026Parameter-Efficient Adaptation of a Multi-Stream Vision-Language Framework for Blind Image Quality Assessment
- 2026Radiology Report Generation for Low-Quality X-Ray Images
- 2024DenoMamba: A fused state-space model for low-dose CT denoising
- 2023IQAGPT: Image Quality Assessment with Vision-language and ChatGPT Models
- 2026Understanding Pure Textual Reasoning for Blind Image Quality Assessment