CAP-IQA: Context-Aware Prompt-Guided CT Image Quality Assessment
Not on the map. Why?
Abstract (arXiv)
Prompt-based methods, which encode medical priors through descriptive text, have been only minimally explored for CT Image Quality Assessment (IQA). While such prompts can embed prior knowledge about diagnostic quality, they often introduce bias by reflecting idealized definitions that may not hold under real-world degradations such as noise, motion artifacts, or scanner variability. To address this, we propose the Context-Aware Prompt-guided Image Quality Assessment (CAP-IQA) framework, which integrates text-level priors with instance-level context prompts and applies causal debiasing to separate idealized knowledge from factual, image-specific degradations. Our framework combines a CNN-based visual encoder with a domain-specific text encoder to assess diagnostic visibility, anatomical clarity, and noise perception in abdominal CT images. The model leverages radiology-style prompts and context-aware fusion to align semantic and perceptual representations. On the 2023 LDCTIQA challenge benchmark, CAP-IQA achieves an overall correlation score of 2.8590 (sum of PLCC, SROCC, and KROCC), surpassing the top-ranked leaderboard team (2.7427) by 4.24%. Moreover, our comprehensive ablation experiments confirm that prompt-guided fusion and the simplified encoder-only design jointly enhance feature alignment and interpretability. Furthermore, evaluation on an in-house dataset of 91,514 pediatric CT images demonstrates the true generalizability of CAP-IQA in assessing perceptual fidelity in a different patient population.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 16 of its 31 references that are in the map. First posted on arXiv 4 Jan 2026.
Builds on
16 of 31 references.
References · 16
- 2020An Image is Worth 16x16 Words: Transformers for Image Recognition at Scalecited by 29,915
- 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,604
- 2021EfficientNetV2: Smaller Models and Faster Trainingcited by 1,127
- 2020Domain-Specific Language Model Pretraining for Biomedical Natural Language Processingcited by 996
- 2022MedCLIP: Contrastive Learning from Unpaired Medical Images and Textcited by 564
- 2019Blind Image Quality Assessment Using A Deep Bilinear Convolutional Neural Networkcited by 301
- 2024Vision-Language Models for Medical Report Generation and Visual Question Answering: A Reviewcited by 121
- 2022Attentions Help CNNs See Better: Attention-based Hybrid Image Quality Assessment Networkcited by 57
- 2023IQAGPT: Image Quality Assessment with Vision-language and ChatGPT Modelscited by 18
- 2024PromptIQA: Boosting the Performance and Generalization for No-Reference Image Quality Assessment via Promptscited by 14
- 2025Are Vision Language Models Ready for Clinical Diagnosis? A 3D Medical Benchmark for Tumor-centric Visual Question Answeringcited by 14
- 2024PCQA: A Strong Baseline for AIGC Quality Assessment Based on Prompt Conditioncited by 6
4 more
- 2024AI-Generated Image Quality Assessment Based on Task-Specific Prompt and Multi-Granularity Similaritycited by 5
- 2024Charting the Path Forward: CT Image Quality Assessment -- An In-Depth Reviewcited by 3
- 2023MD-IQA: Learning Multi-scale Distributed Image Quality Assessment with Semi Supervised Learning for Low Dose CTcited by 2
- 2023Blind CT Image Quality Assessment Using DDPM-derived Content and Transformer-based Evaluatorcited by 1
Built on by
Not cited yet.