mlsanityData to 14 Oct 2026

Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model

arXiv 2308.13072 ↗First posted 24 Aug 2023eess.IV cs.CVcited by 15

On the map: Diffusion models → Medical imaging and segmentation

Abstract (arXiv)

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

Key facts. Cited by 15 papers in the map (data through 14 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. Builds on 19 of its 51 references that are in the map. First posted on arXiv 24 Aug 2023.

Builds on

19 of 51 references.

Closest ancestors · 2

Same direction, newest first

  1. 2022PET image denoising based on denoising diffusion probabilistic models13 Sep
  2. 2022Diffusion Models for Medical Anomaly Detection8 Mar

Other references · 17

  1. 2015Deep Residual Learning for Image Recognitioncited by 52,096
  2. 2020Denoising Diffusion Probabilistic Modelscited by 21,076
  3. 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,713
  4. 2021Swin Transformer: Hierarchical Vision Transformer using Shifted Windowscited by 12,139
  5. 2020Denoising Diffusion Implicit Modelscited by 9,781
  6. 2020Score-Based Generative Modeling through Stochastic Differential Equationscited by 9,122
  7. 2021Diffusion Models Beat GANs on Image Synthesiscited by 8,255
  8. 2022Classifier-Free Diffusion Guidancecited by 5,847
  9. 2021Improved Denoising Diffusion Probabilistic Modelscited by 3,761
  10. 2023Consistency Modelscited by 1,822
  11. 2017Towards Principled Methods for Training Generative Adversarial Networkscited by 464
  12. 2022Conversion Between CT and MRI Images Using Diffusion and Score-Matching Modelscited by 69
5 more
  1. 2023Polyp-SAM: Transfer SAM for Polyp Segmentationcited by 64
  2. 2023Advancing Medical Imaging with Language Models: A Journey from N-grams to ChatGPTcited by 28
  3. 2021PC-HMR: Pose Calibration for 3D Human Mesh Recovery from 2D Images/Videoscited by 25
  4. 2023High Fidelity 3D Hand Shape Reconstruction via Scalable Graph Frequency Decompositioncited by 18
  5. 2022Reducing Positional Variance in Cross-sectional Abdominal CT Slices with Deep Conditional Generative Modelscited by 7

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2024: 4; 2025: 6; 2026: 5.

15 papers.

Sort:

By area:

  1. 20242.5D Multi-view Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-count PET Reconstruction with CT-less Attenuation Correctioncited by 13
  2. 2025PET Image Reconstruction Using Deep Diffusion Image Priorcited by 6
  3. 2024T1-contrast Enhanced MRI Generation from Multi-parametric MRI for Glioma Patients with Latent Tumor Conditioningcited by 3
  4. 2024Adaptive Whole-Body PET Image Denoising Using 3D Diffusion Models with ControlNetcited by 2
  5. 2026M2Diff: Multi-Modality Multi-Task Enhanced Diffusion Model for MRI-Guided Low-Dose PET Enhancementcited by 1
  6. 2026PPDM: Pixel Puzzling Diffusion Model for Speed and Memory Efficient Volumetric Medical Image Translationcited by 1
  7. 2024Cycle-Constrained Adversarial Denoising Convolutional Network for PET Image Denoising: Multi-Dimensional Validation on Large Datasets with Reader Study and Real Low-Dose Datacited by 0
  8. 2025Exploiting network optimization stability for enhanced PET image denoising using deep image priorcited by 0
  9. 2025Physics-Constrained Diffusion Reconstruction with Posterior Correction for Quantitative and Fast PET Imagingcited by 0
  10. 2025Double-Constraint Diffusion Model with Nuclear Regularization for Ultra-low-dose PET Reconstructioncited by 0
  11. 2025Patlak Parametric Image Estimation from Dynamic PET Using Diffusion Model Priorcited by 0
  12. 2025Meta-information Guided Cross-domain Synergistic Diffusion Model for Low-dose PET Reconstructioncited by 0
3 more
  1. 2026Text controllable PET denoisingcited by 0
  2. 2026VLM- and LLM-Driven Multi-Agent System for PET Image Denoisingcited by 0
  3. 2026Flow Matching-Based PET Image Reconstructioncited by 0

Similar, not cited

Close in wording, no citation either way

  1. 2026MAP-Diff: Multi-Anchor Guided Diffusion for Progressive 3D Whole-Body Low-Dose PET Denoising
  2. 2024Dose-aware Diffusion Model for 3D PET Image Denoising: Multi-institutional Validation with Reader Study and Real Low-dose Data
  3. 2026Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy
  4. 2023DDPET-3D: Dose-aware Diffusion Model for 3D Ultra Low-dose PET Imaging
  5. 2024Diffusion Transformer Model With Compact Prior for Low-dose PET Reconstruction
  6. 2025CT-Less Attenuation Correction Using Multiview Ensemble Conditional Diffusion Model on High-Resolution Uncorrected PET Images
  7. 2025Supervised Diffusion-Model-Based PET Image Reconstruction
  8. 20263D Wavelet-Based Structural Priors for Controlled Diffusion in Whole-Body Low-Dose PET Denoising