CT-Less Attenuation Correction Using Multiview Ensemble Conditional Diffusion Model on High-Resolution Uncorrected PET Images
On the map: Diffusion models → Medical imaging and segmentation
Abstract (arXiv)
Accurate quantification in positron emission tomography (PET) is essential for accurate diagnostic results and effective treatment tracking. A major issue encountered in PET imaging is attenuation. Attenuation refers to the diminution of photon detected as they traverse biological tissues before reaching detectors. When such corrections are absent or inadequate, this signal degradation can introduce inaccurate quantification, making it difficult to differentiate benign from malignant conditions, and can potentially lead to misdiagnosis. Typically, this correction is done with co-computed Computed Tomography (CT) imaging to obtain structural data for calculating photon attenuation across the body. However, this methodology subjects patients to extra ionizing radiation exposure, suffers from potential spatial misregistration between PET/CT imaging sequences, and demands costly equipment infrastructure. Emerging advances in neural network architectures present an alternative approach via synthetic CT image synthesis. Our investigation reveals that Conditional Denoising Diffusion Probabilistic Models (DDPMs) can generate high quality CT images from non attenuation corrected PET images in order to correct attenuation. By utilizing all three orthogonal views from non-attenuation-corrected PET images, the DDPM approach combined with ensemble voting generates higher quality pseudo-CT images with reduced artifacts and improved slice-to-slice consistency. Results from a study of 159 head scans acquired with the Siemens Biograph Vision PET/CT scanner demonstrate both qualitative and quantitative improvements in pseudo-CT generation. The method achieved a mean absolute error of 32 ± 10.4 HU on the CT images and an average error of (1.48 ± 0.68)% across all regions of interest when comparing PET images reconstructed using the attenuation map of the generated pseudo-CT versus the true CT.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. Builds on 5 of its 27 references that are in the map. First posted on arXiv 28 Oct 2025.
Builds on
5 of 27 references.
Closest ancestors · 1
Same direction, newest first
Other references · 4
- 2020Denoising Diffusion Probabilistic Modelscited by 21,076
- 2021Improved Denoising Diffusion Probabilistic Modelscited by 3,761
- 2018Attention U-Net: Learning Where to Look for the Pancreascited by 1,435
- 2023Efficient Diffusion Training via Min-SNR Weighting Strategycited by 246
Built on by
Not cited yet.
Similar, not cited
Close in wording, no citation either way
- 2024Adaptive Whole-Body PET Image Denoising Using 3D Diffusion Models with ControlNet
- 2026Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy
- 2025Physics-Constrained Diffusion Reconstruction with Posterior Correction for Quantitative and Fast PET Imaging
- 2023Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model
- 2024Dose-aware Diffusion Model for 3D PET Image Denoising: Multi-institutional Validation with Reader Study and Real Low-dose Data
- 2025PADM: A Physics-aware Diffusion Model for Attenuation Correction
- 2024CT to PET Translation: A Large-scale Dataset and Domain-Knowledge-Guided Diffusion Approach
- 2026MAP-Diff: Multi-Anchor Guided Diffusion for Progressive 3D Whole-Body Low-Dose PET Denoising