Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video
Not on the map. Why?
Abstract (arXiv)
Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.
Key facts. Cited by 2 papers in the map (data through 7 Oct 2026). Builds on 16 of its 81 references that are in the map. First posted on arXiv 9 Jan 2024.
Builds on
16 of 81 references.
References · 16
- 2016Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localizationcited by 6,690
- 2019Searching for MobileNetV3cited by 1,984
- 2016Joint Face Detection and Alignment using Multi-task Cascaded Convolutional Networkscited by 895
- 2018BAM: Bottleneck Attention Modulecited by 171
- 2018DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networkscited by 153
- 2022FILM: Frame Interpolation for Large Motioncited by 149
- 2020Multi-Task Temporal Shift Attention Networks for On-Device Contactless Vitals Measurementcited by 133
- 2019Remote Photoplethysmograph Signal Measurement from Facial Videos Using Spatio-Temporal Networkscited by 126
- 2021PhysFormer: Facial Video-based Physiological Measurement with Temporal Difference Transformercited by 118
- 2022rPPG-Toolbox: Deep Remote PPG Toolboxcited by 63
- 2018VIPL-HR: A Multi-modal Database for Pulse Estimation from Less-constrained Face Videocited by 57
- 2023PhysFormer++: Facial Video-based Physiological Measurement with SlowFast Temporal Difference Transformercited by 46
4 more
- 2020AutoHR: A Strong End-to-end Baseline for Remote Heart Rate Measurement with Neural Searchingcited by 39
- 2022Facial Video-based Remote Physiological Measurement via Self-supervised Learningcited by 22
- 2021The First Vision For Vitals (V4V) Challenge for Non-Contact Video-Based Physiological Estimationcited by 19
- 2023Dual-path TokenLearner for Remote Photoplethysmography-based Physiological Measurement with Facial Videoscited by 15
Built on by
Citing papers per year: 2024: 1; 2025: 1.
2 papers.