mlsanityData to 7 Oct 2026

PPFM: Image denoising in photon-counting CT using single-step posterior sampling Poisson flow generative models

arXiv 2312.09754 ↗First posted 15 Dec 2023eess.IV cs.CV physics.med-phcited by 4

On the map: Diffusion models → Medical imaging and segmentation

Abstract (arXiv)

Diffusion and Poisson flow models have shown impressive performance in a wide range of generative tasks, including low-dose CT image denoising. However, one limitation in general, and for clinical applications in particular, is slow sampling. Due to their iterative nature, the number of function evaluations (NFE) required is usually on the order of 10-103, both for conditional and unconditional generation. In this paper, we present posterior sampling Poisson flow generative models (PPFM), a novel image denoising technique for low-dose and photon-counting CT that produces excellent image quality whilst keeping NFE=1. Updating the training and sampling processes of Poisson flow generative models (PFGM)++, we learn a conditional generator which defines a trajectory between the prior noise distribution and the posterior distribution of interest. We additionally hijack and regularize the sampling process to achieve NFE=1. Our results shed light on the benefits of the PFGM++ framework compared to diffusion models. In addition, PPFM is shown to perform favorably compared to current state-of-the-art diffusion-style models with NFE=1, consistency models, as well as popular deep learning and non-deep learning-based image denoising techniques, on clinical low-dose CT images and clinical images from a prototype photon-counting CT system.

Key facts. Cited by 4 papers in the map (data through 7 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. Builds on 28 of its 69 references that are in the map. First posted on arXiv 15 Dec 2023.

Builds on

28 of 69 references.

Closest ancestors · 2

Same direction, newest first

  1. 2023Diffusion Probabilistic Priors for Zero-Shot Low-Dose CT Image Denoising25 May
  2. 2021Solving Inverse Problems in Medical Imaging with Score-Based Generative Models15 Nov

Other references · 26

  1. 2014Adam: A Method for Stochastic Optimizationcited by 36,960
  2. 2020Denoising Diffusion Probabilistic Modelscited by 20,851
  3. 2018The Unreasonable Effectiveness of Deep Features as a Perceptual Metriccited by 11,029
  4. 2020Denoising Diffusion Implicit Modelscited by 9,655
  5. 2020Score-Based Generative Modeling through Stochastic Differential Equationscited by 8,964
  6. 2015Deep Unsupervised Learning using Nonequilibrium Thermodynamicscited by 7,005
  7. 2021Improved Denoising Diffusion Probabilistic Modelscited by 3,736
  8. 2022Elucidating the Design Space of Diffusion-Based Generative Modelscited by 2,994
  9. 2023Consistency Modelscited by 1,778
  10. 2021Image Super-Resolution via Iterative Refinementcited by 1,506
  11. 2021Palette: Image-to-Image Diffusion Modelscited by 1,296
  12. 2021Come-Closer-Diffuse-Faster: Accelerating Conditional Diffusion Models for Inverse Problems through Stochastic Contractioncited by 306
14 more
  1. 2014One weird trick for parallelizing convolutional neural networkscited by 264
  2. 2017Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)cited by 224
  3. 2023Fine-tuning Language Models for Factualitycited by 219
  4. 2021Conditional Image Generation with Score-Based Diffusion Modelscited by 195
  5. 2017Low Dose CT Image Denoising Using a Generative Adversarial Network with Wasserstein Distance and Perceptual Losscited by 161
  6. 2022Poisson Flow Generative Modelscited by 95
  7. 2023PFGM++: Unlocking the Potential of Physics-Inspired Generative Modelscited by 73
  8. 2022MR Image Denoising and Super-Resolution Using Regularized Reverse Diffusioncited by 66
  9. 2018Can Deep Learning Outperform Modern Commercial CT Image Reconstruction Methods?cited by 53
  10. 2022CTformer: Convolution-free Token2Token Dilated Vision Transformer for Low-dose CT Denoisingcited by 46
  11. 2021TransCT: Dual-path Transformer for Low Dose Computed Tomographycited by 35
  12. 2022Low-Dose CT Denoising via Sinogram Inner-Structure Transformercited by 13
  13. 2023Systematic Review on Learning-based Spectral CTcited by 6
  14. 2023JCCS-PFGM: A Novel Circle-Supervision based Poisson Flow Generative Model for Multiphase CECT Progressive Low-Dose Reconstruction with Joint Conditioncited by 5

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2024: 1; 2025: 2; 2026: 1.

4 papers.

Similar, not cited

Close in wording, no citation either way

  1. 2024Photon-counting CT using a Conditional Diffusion Model for Super-resolution and Texture-preservation
  2. 2026RDDM: A Residual-Driven Drifting Model for High-Fidelity Low-Dose CT Denoising
  3. 2025Pseudoinverse Diffusion Models for Generative CT Image Reconstruction from Low Dose Data
  4. 2022Low-Dose CT Using Denoising Diffusion Probabilistic Model for 20× Speedup
  5. 20243D Photon Counting CT Image Super-Resolution Using Conditional Diffusion Model
  6. 2026Distilling Photon-Counting CT into Routine Chest CT through Clinically Validated Degradation Modeling
  7. 2025MAN: Latent Diffusion Enhanced Multistage Anti-Noise Network for Efficient and High-Quality Low-Dose CT Image Denoising
  8. 2025AST-n: A Fast Sampling Approach for Low-Dose CT Reconstruction using Diffusion Models