mlsanityData to 14 Oct 2026

Parallel Diffusion Model-based Sparse-view Cone-beam Breast CT

arXiv 2303.12861 ↗First posted 22 Mar 2023eess.IV cs.LG eess.SPcited by 7

On the map: Diffusion models → Medical imaging and segmentation

Abstract (arXiv)

Breast cancer is the most prevalent cancer among women worldwide, and early detection is crucial for reducing its mortality rate and improving quality of life. Dedicated breast computed tomography (CT) scanners offer better image quality than mammography and tomosynthesis in general but at higher radiation dose. To enable breast CT for cancer screening, the challenge is to minimize the radiation dose without compromising image quality, according to the ALARA principle (as low as reasonably achievable). Over the past years, deep learning has shown remarkable successes in various tasks, including low-dose CT especially few-view CT. Currently, the diffusion model presents the state of the art for CT reconstruction. To develop the first diffusion model-based breast CT reconstruction method, here we report innovations to address the large memory requirement for breast cone-beam CT reconstruction and high computational cost of the diffusion model. Specifically, in this study we transform the cutting-edge Denoising Diffusion Probabilistic Model (DDPM) into a parallel framework for sub-volume-based sparse-view breast CT image reconstruction in projection and image domains. This novel approach involves the concurrent training of two distinct DDPM models dedicated to processing projection and image data synergistically in the dual domains. Our experimental findings reveal that this method delivers competitive reconstruction performance at half to one-third of the standard radiation doses. This advancement demonstrates an exciting potential of diffusion-type models for volumetric breast reconstruction at high-resolution with much-reduced radiation dose and as such hopefully redefines breast cancer screening and diagnosis.

Key facts. Cited by 7 papers in the map (data through 14 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. Builds on 22 of its 51 references that are in the map. First posted on arXiv 22 Mar 2023.

Builds on

22 of 51 references.

Closest ancestors · 1

Same direction, newest first

  1. 2022Patch-Based Denoising Diffusion Probabilistic Model for Sparse-View CT Reconstruction18 Nov

Other references · 21

  1. 2020Denoising Diffusion Probabilistic Modelscited by 21,076
  2. 2021High-Resolution Image Synthesis with Latent Diffusion Modelscited by 18,863
  3. 2020Denoising Diffusion Implicit Modelscited by 9,781
  4. 2020Score-Based Generative Modeling through Stochastic Differential Equationscited by 9,122
  5. 2021Diffusion Models Beat GANs on Image Synthesiscited by 8,255
  6. 2022Generative Adversarial Networkscited by 5,627
  7. 2022DPM-Solver: A Fast ODE Solver for Diffusion Probabilistic Model Sampling in Around 10 Stepscited by 1,979
  8. 2023Consistency Modelscited by 1,822
  9. 2021Image Super-Resolution via Iterative Refinementcited by 1,511
  10. 2022RePaint: Inpainting using Denoising Diffusion Probabilistic Modelscited by 1,430
  11. 2022DPM-Solver++: Fast Solver for Guided Sampling of Diffusion Probabilistic Modelscited by 938
  12. 2016Deep Convolutional Neural Network for Inverse Problems in Imagingcited by 433
9 more
  1. 2017Learned Primal-dual Reconstructioncited by 251
  2. 2017Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)cited by 224
  3. 2017Low Dose CT Image Denoising Using a Generative Adversarial Network with Wasserstein Distance and Perceptual Losscited by 162
  4. 2022Poisson Flow Generative Modelscited by 95
  5. 2017CNN-Based Projected Gradient Descent for Consistent Image Reconstructioncited by 77
  6. 2020FISTA-Net: Learning A Fast Iterative Shrinkage Thresholding Network for Inverse Problems in Imagingcited by 74
  7. 2019Momentum-Net: Fast and convergent iterative neural network for inverse problemscited by 38
  8. 2016A Perspective on Deep Imagingcited by 16
  9. 2022Physics-/Model-Based and Data-Driven Methods for Low-Dose Computed Tomography: A surveycited by 14

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2023: 1; 2024: 2; 2025: 3; 2026: 1.

7 papers.

Similar, not cited

Close in wording, no citation either way

  1. 2024CT-SDM: A Sampling Diffusion Model for Sparse-View CT Reconstruction across All Sampling Rates
  2. 2025Noise-Inspired Diffusion Model for Generalizable Low-Dose CT Reconstruction
  3. 2026Conditional Diffusion Posterior Alignment for Sparse-View CT Reconstruction
  4. 2023Diffusion Denoising for Low-Dose-CT Model
  5. 2023DDMM-Synth: A Denoising Diffusion Model for Cross-modal Medical Image Synthesis with Sparse-view Measurement Embedding
  6. 2024Integrating Deep Unfolding with Direct Diffusion Bridges for Computed Tomography Reconstruction
  7. 2024Partitioned Hankel-based Diffusion Models for Few-shot Low-dose CT Reconstruction
  8. 2023Diffusion Prior Regularized Iterative Reconstruction for Low-dose CT