mlsanityData to 7 Oct 2026

HC3L-Diff: Hybrid conditional latent diffusion with high frequency enhancement for CBCT-to-CT synthesis

arXiv 2411.01575 ↗First posted 3 Nov 2024eess.IV cs.CVcited by 2

On the map: Diffusion models → Medical imaging and segmentation

Abstract (arXiv)

Background: Cone-beam computed tomography (CBCT) plays a crucial role in image-guided radiotherapy, but artifacts and noise make them unsuitable for accurate dose calculation. Artificial intelligence methods have shown promise in enhancing CBCT quality to produce synthetic CT (sCT) images. However, existing methods either produce images of suboptimal quality or incur excessive time costs, failing to satisfy clinical practice standards. Methods and materials: We propose a novel hybrid conditional latent diffusion model for efficient and accurate CBCT-to-CT synthesis, named HC3L-Diff. We employ the Unified Feature Encoder (UFE) to compress images into a low-dimensional latent space, thereby optimizing computational efficiency. Beyond the use of CBCT images, we propose integrating its high-frequency knowledge as a hybrid condition to guide the diffusion model in generating sCT images with preserved structural details. This high-frequency information is captured using our designed High-Frequency Extractor (HFE). During inference, we utilize denoising diffusion implicit model to facilitate rapid sampling. We construct a new in-house prostate dataset with paired CBCT and CT to validate the effectiveness of our method. Result: Extensive experimental results demonstrate that our approach outperforms state-of-the-art methods in terms of sCT quality and generation efficiency. Moreover, our medical physicist conducts the dosimetric evaluations to validate the benefit of our method in practical dose calculation, achieving a remarkable 93.8% gamma passing rate with a 2%/2mm criterion, superior to other methods. Conclusion: The proposed HC3L-Diff can efficiently achieve high-quality CBCT-to-CT synthesis in only over 2 mins per patient. Its promising performance in dose calculation shows great potential for enhancing real-world adaptive radiotherapy.

Key facts. Cited by 2 papers in the map (data through 7 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. Builds on 15 of its 43 references that are in the map. First posted on arXiv 3 Nov 2024.

Builds on

15 of 43 references.

Closest ancestors · 3

Same direction, newest first

  1. 2023Energy-Guided Diffusion Model for CBCT-to-CT Synthesis7 Aug
  2. 2023Zero-shot Medical Image Translation via Frequency-Guided Diffusion Models5 Apr
  3. 2023CoLa-Diff: Conditional Latent Diffusion Model for Multi-Modal MRI Synthesis24 Mar

Other references · 12

  1. 2020Denoising Diffusion Probabilistic Modelscited by 20,851
  2. 2021High-Resolution Image Synthesis with Latent Diffusion Modelscited by 18,694
  3. 2020Denoising Diffusion Implicit Modelscited by 9,655
  4. 2021Diffusion Models Beat GANs on Image Synthesiscited by 8,185
  5. 2015Deep Unsupervised Learning using Nonequilibrium Thermodynamicscited by 7,005
  6. 2017Neural Discrete Representation Learningcited by 4,650
  7. 2020Taming Transformers for High-Resolution Image Synthesiscited by 3,229
  8. 2022Paint by Example: Exemplar-based Image Editing with Diffusion Modelscited by 489
  9. 2023ResShift: Efficient Diffusion Model for Image Super-resolution by Residual Shiftingcited by 360
  10. 2021Deep learning-based synthetic-CT generation in radiotherapy and PET: a reviewcited by 28
  11. 2023Structure-Preserving Synthesis: MaskGAN for Unpaired MR-CT Translationcited by 19
  12. 2023Is attention all you need in medical image analysis? A reviewcited by 12

Built on by

Cited by year

Citing papers per year: 2025: 2.

2 papers.

Similar, not cited

Close in wording, no citation either way

  1. 2026Toward CT-Equivalent Image Quality in Low-Dose Radiotherapy Planning: Conditional Diffusion-Based CBCT-to-CT Synthesis and the Impact of CBCT Input Representation
  2. 2026EPC-3D-Diff: Equivariant Physics Consistent Conditional 3D Latent Diffusion for CBCT to CT Synthesis
  3. 2024Improving Cone-Beam CT Image Quality with Knowledge Distillation-Enhanced Diffusion Model in Imbalanced Data Settings
  4. 2026Cone-Beam CT Image Quality Enhancement Using A Latent Diffusion Model Trained with Simulated CBCT Artifacts
  5. 2024Prior Frequency Guided Diffusion Model for Limited Angle (LA)-CBCT Reconstruction
  6. 2026TAFG-MAN: Timestep-Adaptive Frequency-Gated Latent Diffusion for Efficient and High-Quality Low-Dose CT Image Denoising
  7. 2025FoundDiff: Foundational Diffusion Model for Generalizable Low-Dose CT Denoising
  8. 2025Flow Matching for Conditional MRI-CT and CBCT-CT Image Synthesis