Harmonizing Flows: Leveraging normalizing flows for unsupervised and source-free MRI harmonization
Not on the map. Why?
Abstract (arXiv)
Lack of standardization and various intrinsic parameters for magnetic resonance (MR) image acquisition results in heterogeneous images across different sites and devices, which adversely affects the generalization of deep neural networks. To alleviate this issue, this work proposes a novel unsupervised harmonization framework that leverages normalizing flows to align MR images, thereby emulating the distribution of a source domain. The proposed strategy comprises three key steps. Initially, a normalizing flow network is trained to capture the distribution characteristics of the source domain. Then, we train a shallow harmonizer network to reconstruct images from the source domain via their augmented counterparts. Finally, during inference, the harmonizer network is updated to ensure that the output images conform to the learned source domain distribution, as modeled by the normalizing flow network. Our approach, which is unsupervised, source-free, and task-agnostic is assessed in the context of both adults and neonatal cross-domain brain MRI segmentation, as well as neonatal brain age estimation, demonstrating its generalizability across tasks and population demographics. The results underscore its superior performance compared to existing methodologies. The code is available at https://github.com/farzad-bz/Harmonizing-Flows
Key facts. Cited by 4 papers in the map (data through 7 Oct 2026). Builds on 38 of its 77 references that are in the map. First posted on arXiv 22 Jul 2024.
Builds on
38 of 77 references.
References · 38
- 2015Deep Residual Learning for Image Recognitioncited by 51,809
- 2016Improved Techniques for Training GANscited by 2,938
- 2016Density estimation using Real NVPcited by 2,029
- 2018Glow: Generative Flow with Invertible 1x1 Convolutionscited by 1,539
- 2020Do We Really Need to Access the Source Data? Source Hypothesis Transfer for Unsupervised Domain Adaptationcited by 844
- 2022Efficient Test-Time Model Adaptation without Forgettingcited by 467
- 2023Towards Stable Test-Time Adaptation in Dynamic Wild Worldcited by 409
- 2021CFLOW-AD: Real-Time Unsupervised Anomaly Detection with Localization via Conditional Normalizing Flowscited by 320
- 2018Aleatoric uncertainty estimation with test-time augmentation for medical image segmentation with convolutional neural networkscited by 278
- 2019Flow++: Improving Flow-Based Generative Models with Variational Dequantization and Architecture Designcited by 258
- 2020Why Normalizing Flows Fail to Detect Out-of-Distribution Datacited by 220
- 2022Parameter-free Online Test-time Adaptationcited by 184
26 more
- 2020MoFlow: An Invertible Flow Model for Generating Molecular Graphscited by 183
- 2020Unsupervised Bidirectional Cross-Modality Adaptation via Deeply Synergistic Image and Feature Alignment for Medical Image Segmentationcited by 134
- 2016Unsupervised domain adaptation in brain lesion segmentation with adversarial networkscited by 125
- 2019Noise Flow: Noise Modeling with Conditional Normalizing Flowscited by 108
- 2020Test-Time Adaptable Neural Networks for Robust Medical Image Segmentationcited by 102
- 2018Distribution Matching Losses Can Hallucinate Features in Medical Image Translationcited by 99
- 2022USB: A Unified Semi-supervised Learning Benchmark for Classificationcited by 95
- 2021Test-Time Adaptation to Distribution Shift by Confidence Maximization and Input Transformationcited by 67
- 2020Tent: Fully Test-time Adaptation by Entropy Minimizationcited by 59
- 2021Source-Free Domain Adaptation for Image Segmentationcited by 45
- 2019AlignFlow: Cycle Consistent Learning from Multiple Domains via Normalizing Flowscited by 33
- 2022TTTFlow: Unsupervised Test-Time Training with Normalizing Flowcited by 33
- 2022MT-UDA: Towards Unsupervised Cross-modality Medical Image Segmentation with Limited Source Labelscited by 24
- 20163D fully convolutional networks for subcortical segmentation in MRI: A large-scale studycited by 19
- 2023Diffusion Models for Contrast Harmonization of Magnetic Resonance Imagescited by 19
- 2022HACA3: A Unified Approach for Multi-site MR Image Harmonizationcited by 17
- 2021Information-based Disentangled Representation Learning for Unsupervised MR Harmonizationcited by 16
- 2021ImUnity: a generalizable VAE-GAN solution for multicenter MR image harmonizationcited by 16
- 2021Harmonization with Flow-based Causal Inferencecited by 14
- 2022Unsupervised Model Adaptation for Source-free Segmentation of Medical Imagescited by 13
- 2020Log-Likelihood Ratio Minimizing Flows: Towards Robust and Quantifiable Neural Distribution Alignmentcited by 10
- 2024Neighbor-Aware Calibration of Segmentation Networks with Penalty-Based Constraintscited by 7
- 2024Quantitative Metrics for Benchmarking Medical Image Harmonizationcited by 6
- 2023Harmonizing Flows: Unsupervised MR harmonization based on normalizing flowscited by 5
- 2023BlindHarmony: "Blind" Harmonization for MR Images via Flow modelcited by 5
- 2020Realistic Image Normalization for Multi-Domain Segmentationcited by 3
Built on by
Citing papers per year: 2025: 1; 2026: 3.
4 papers.
- 2026IHF-Harmony: Multi-Modality Magnetic Resonance Images Harmonization using Invertible Hierarchy Flow Modelcited by 1
- 2025Efficient and robust 3D blind harmonization for large domain gapscited by 0
- 2026HARP: HARmonizing in-vivo diffusion MRI using Phantom-only trainingcited by 0
- 2026CAHAL: Clinically Applicable resolution enHAncement for Low-resolution MRI scanscited by 0
- 2026CAHAL: Clinically Applicable resolution enHAncement for Low-resolution MRI scans20 Apr 2026
- 2026HARP: HARmonizing in-vivo diffusion MRI using Phantom-only training5 Mar 2026
- 2026IHF-Harmony: Multi-Modality Magnetic Resonance Images Harmonization using Invertible Hierarchy Flow Model25 Feb 2026
- 2025Efficient and robust 3D blind harmonization for large domain gaps30 Apr 2025