Constraint Latent Space Matters: An Anti-anomalous Waveform Transformation Solution from Photoplethysmography to Arterial Blood Pressure
Not on the map. Why?
Abstract (arXiv)
Arterial blood pressure (ABP) holds substantial promise for proactive cardiovascular health management. Notwithstanding its potential, the invasive nature of ABP measurements confines their utility primarily to clinical environments, limiting their applicability for continuous monitoring beyond medical facilities. The conversion of photoplethysmography (PPG) signals into ABP equivalents has garnered significant attention due to its potential in revolutionizing cardiovascular disease management. Recent strides in PPG-to-ABP prediction encompass the integration of generative and discriminative models. Despite these advances, the efficacy of these models is curtailed by the latent space shift predicament, stemming from alterations in PPG data distribution across disparate hardware and individuals, potentially leading to distorted ABP waveforms. To tackle this problem, we present an innovative solution named the Latent Space Constraint Transformer (LSCT), leveraging a quantized codebook to yield robust latent spaces by employing multiple discretizing bases. To facilitate improved reconstruction, the Correlation-boosted Attention Module (CAM) is introduced to systematically query pertinent bases on a global scale. Furthermore, to enhance expressive capacity, we propose the Multi-Spectrum Enhancement Knowledge (MSEK), which fosters local information flow within the channels of latent code and provides additional embedding for reconstruction. Through comprehensive experimentation on both publicly available datasets and a private downstream task dataset, the proposed approach demonstrates noteworthy performance enhancements compared to existing methods. Extensive ablation studies further substantiate the effectiveness of each introduced module.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 19 of its 53 references that are in the map. First posted on arXiv 23 Feb 2024.
Builds on
19 of 53 references.
References · 19
- 2014Adam: A Method for Stochastic Optimizationcited by 36,960
- 2020Denoising Diffusion Probabilistic Modelscited by 20,851
- 2019PyTorch: An Imperative Style, High-Performance Deep Learning Librarycited by 20,160
- 2021Swin Transformer: Hierarchical Vision Transformer using Shifted Windowscited by 12,082
- 2016SGDR: Stochastic Gradient Descent with Warm Restartscited by 4,993
- 2017Neural Discrete Representation Learningcited by 4,650
- 2021CoAtNet: Marrying Convolution and Attention for All Data Sizescited by 566
- 2019InceptionTime: Finding AlexNet for Time Series Classificationcited by 386
- 2017Real-valued (Medical) Time Series Generation with Recurrent Conditional GANscited by 329
- 2023Vector Quantized Time Series Generation with a Bidirectional Prior Modelcited by 49
- 2020CardioGAN: Attentive Generative Adversarial Network with Dual Discriminators for Synthesis of ECG from PPGcited by 34
- 2017Style Transfer for Anime Sketches with Enhanced Residual U-net and Auxiliary Classifier GANcited by 28
7 more
- 2022TTS-CGAN: A Transformer Time-Series Conditional GAN for Biosignal Data Augmentationcited by 20
- 2020PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms using Fully Convolutional Neural Networkscited by 18
- 2022Domain Adaptation Meets Zero-Shot Learning: An Annotation-Efficient Approach to Multi-Modality Medical Image Segmentationcited by 16
- 2022Performer: A Novel PPG-to-ECG Reconstruction Transformer for a Digital Biomarker of Cardiovascular Disease Detectioncited by 13
- 2021Estimation of Continuous Blood Pressure from PPG via a Federated Learning Approachcited by 12
- 2022All Grains, One Scheme (AGOS): Learning Multi-grain Instance Representation for Aerial Scene Classificationcited by 6
- 2021BP-Net: Efficient Deep Learning for Continuous Arterial Blood Pressure Estimation using Photoplethysmogramcited by 5
Built on by
Not cited yet.