Assessment of Deep Learning-based Heart Rate Estimation using Remote Photoplethysmography under Different Illuminations

arXiv 2107.13193 ↗First posted 28 Jul 2021cs.CVcited by 6

Not on the map. Why?

Abstract (arXiv)

Remote photoplethysmography (rPPG) monitors heart rate without requiring physical contact, which allows for a wide variety of applications. Deep learning-based rPPG have demonstrated superior performance over the traditional approaches in controlled context. However, the lighting situation in indoor space is typically complex, with uneven light distribution and frequent variations in illumination. It lacks a fair comparison of different methods under different illuminations using the same dataset. In this paper, we present a public dataset, namely the BH-rPPG dataset, which contains data from thirty five subjects under three illuminations: low, medium, and high illumination. We also provide the ground truth heart rate measured by an oximeter. We evaluate the performance of three deep learning-based methods (Deepphys, rPPGNet, and Physnet) to that of four traditional methods (CHROM, GREEN, ICA, and POS) using two public datasets: the UBFC-rPPG dataset and the BH-rPPG dataset. The experimental results demonstrate that traditional methods are generally more resistant to fluctuating illuminations. We found that the Physnet achieves lowest mean absolute error (MAE) among deep learning-based method under medium illumination, whereas the CHROM achieves 1.04 beats per minute (BPM), outperforming the Physnet by 80%. Additionally, we investigate potential methods for improving performance of deep learning-based methods. We find that brightness augmentation make model more robust to variation illumination. These findings suggest that while developing deep learning-based heart rate estimation algorithms, illumination variation should be taken into account. This work serves as a benchmark for rPPG performance evaluation and it opens a pathway for future investigation into deep learning-based rPPG under illumination variations.

Key facts. Cited by 6 papers in the map (data through 7 Oct 2026). Builds on 13 of its 47 references that are in the map. First posted on arXiv 28 Jul 2021.

Builds on

13 of 47 references.

References · 13

  1. 2019PyTorch: An Imperative Style, High-Performance Deep Learning Librarycited by 20,160
  2. 2020Zero-Reference Deep Curve Estimation for Low-Light Image Enhancementcited by 541
  3. 2018DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networkscited by 153
  4. 2019Remote Photoplethysmograph Signal Measurement from Facial Videos Using Spatio-Temporal Networkscited by 126
  5. 2019RhythmNet: End-to-end Heart Rate Estimation from Face via Spatial-temporal Representationcited by 104
  6. 2019Remote Heart Rate Measurement from Highly Compressed Facial Videos: an End-to-end Deep Learning Solution with Video Enhancementcited by 86
  7. 2020Video-based Remote Physiological Measurement via Cross-verified Feature Disentanglingcited by 78
  8. 2019Attention Guided Low-light Image Enhancement with a Large Scale Low-light Simulation Datasetcited by 65
  9. 2020Meta-rPPG: Remote Heart Rate Estimation Using a Transductive Meta-Learnercited by 58
  10. 2018VIPL-HR: A Multi-modal Database for Pulse Estimation from Less-constrained Face Videocited by 57
  11. 2017A Reproducible Study on Remote Heart Rate Measurementcited by 49
  12. 2019Analysis of CNN-based remote-PPG to understand limitations and sensitivitiescited by 19
1 more
  1. 2019iPhys: An Open Non-Contact Imaging-Based Physiological Measurement Toolboxcited by 8

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2022: 3; 2023: 0; 2024: 1; 2025: 1; 2026: 1.

6 papers.