mlsanityData to 7 Oct 2026

Source-Dependent Deference in Medical Imaging Agents Under Falsified Findings: A Pilot Audit

arXiv 2608.29800 ↗First posted 30 Aug 2026cs.CVcited by 0

Not on the map. Why?

Abstract (arXiv)

Tool-using agents are being proposed for medical imaging, and their behaviour when a tool returns a false finding is largely unmeasured. We audit whether a ReAct-style tool-calling agent abandons an answer it has already given correctly once a falsified finding arrives, and whether that depends on how the finding is presented. On 20 VQA-RAD closed questions across four vendor-designated model tiers, the agent commits to an answer from the image alone; a negated finding is then delivered either as JSON from an analyze_image tool the agent invokes itself, or as quoted prose attributed to a radiologist. Our outcome is the commission-error rate over cases answered correctly without any tool. Deference is much higher under the prose-attributed claim: at the strongest tier the agent revised its correct answer in 10 of 13 cases against 1 of 13 under the tool (exact McNemar p=0.0039, Holm-adjusted 0.012). We do not claim this isolates the source label. Attribution travels with the delivery channel in our design, and exposure differs because the tool claim reaches the agent only when it calls the tool. The finding is a joint source-and-delivery asymmetry from a small-scale pilot whose pre-specified stopping rule was not met.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 12 of its 29 references that are in the map. First posted on arXiv 30 Aug 2026.

Builds on

12 of 29 references.

References · 12

  1. 2025MedRAX: Medical Reasoning Agent for Chest X-raycited by 68
  2. 2025EchoBench: Benchmarking Sycophancy in Medical Large Vision-Language Modelscited by 8
  3. 2026ToolFailBench: Diagnosing Tool-Use Failures in LLM Agentscited by 8
  4. 2026RadAgent: A tool-using AI agent for stepwise interpretation of chest computed tomographycited by 6
  5. 2026MedOpenClaw and MedFlowBench: Auditing Medical Agents in Full-Study Workflowscited by 5
  6. 2026When Correct Beliefs Collapse: Epistemic Resilience of LLMs under Clinical Pressurecited by 4
  7. 2025Selective Prediction Reduces the Negative Effects of Automation Bias Overall but Increases False Negativescited by 2
  8. 2026ProtoMedAgent: Multimodal Clinical Interpretability via Privacy-Aware Agentic Workflowscited by 2
  9. 2026Counterfactual Evaluation Reveals Hidden Capability Profiles in Clinical LLMs and Agentscited by 2
  10. 2026DUCX: Decomposing Unfairness in Tool-Using Chest X-ray Agentscited by 1
  11. 2026Mind the Tool Failures: Achieving Synergistic Tool Gains for Medical Agentscited by 1
  12. 2026MedPRESS: A Multi-turn Benchmark for Patient-Pressure-Induced Medical Sycophancy in LLMscited by 1

Built on by

Not cited yet.

Similar, not cited

Close in wording, no citation either way

  1. 2026Forensic Reproducibility Audit of a Radiology Vision-Language Model Benchmark: From Intended Protocol to Released Artifact
  2. 2026MedVIGIL: Evaluating Trustworthy Medical VLMs Under Broken Visual Evidence
  3. 2026AgentsEval: Clinically Faithful Evaluation of Medical Imaging Reports via Multi-Agent Reasoning
  4. 2026ABRA: Agent Benchmark for Radiology Applications
  5. 2025Clinically Grounded Agent-based Report Evaluation: An Interpretable Metric for Radiology Report Generation
  6. 2026ProvenanceGuard: Source-Aware Factuality Verification for MCP-Based LLM Agents
  7. 2026VERITAS: A Multi-Agent Co-Scientist for Verifiable Image-Derived Hypothesis Testing ↗
  8. 2023Explainable AI And Visual Reasoning: Insights From Radiology