3D CBCT Artefact Removal Using Perpendicular Score-Based Diffusion Models
On the map: Diffusion models → Medical imaging and segmentation
Abstract (arXiv)
Cone-beam computed tomography (CBCT) is a widely used 3D imaging technique in dentistry, offering high-resolution images while minimising radiation exposure for patients. However, CBCT is highly susceptible to artefacts arising from high-density objects such as dental implants, which can compromise image quality and diagnostic accuracy. To reduce artefacts, implant inpainting in the sequence of projections plays a crucial role in many artefact reduction approaches. Recently, diffusion models have achieved state-of-the-art results in image generation and have widely been applied to image inpainting tasks. However, to our knowledge, existing diffusion-based methods for implant inpainting operate on independent 2D projections. This approach neglects the correlations among individual projections, resulting in inconsistencies in the reconstructed images. To address this, we propose a 3D dental implant inpainting approach based on perpendicular score-based diffusion models, each trained in two different planes and operating in the projection domain. The 3D distribution of the projection series is modelled by combining the two 2D score-based diffusion models in the sampling scheme. Our results demonstrate the method's effectiveness in producing high-quality, artefact-reduced 3D CBCT images, making it a promising solution for improving clinical imaging.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. Builds on 6 of its 20 references that are in the map. First posted on arXiv 6 Mar 2026.
Builds on
6 of 20 references.
Closest ancestors · 3
Same direction, newest first
- 2024WDM: 3D Wavelet Diffusion Models for High-Resolution Medical Image Synthesis29 Feb
- 2023Improving 3D Imaging with Pre-Trained Perpendicular 2D Diffusion Models15 Mar
- 2022Metal Inpainting in CBCT Projections Using Score-based Generative Model20 Sep
Other references · 3
- 2020Score-Based Generative Modeling through Stochastic Differential Equationscited by 8,964
- 2022Diffusion Posterior Sampling for General Noisy Inverse Problemscited by 1,375
- 2019DuDoNet: Dual Domain Network for CT Metal Artifact Reductioncited by 68
Built on by
Not cited yet.
Similar, not cited
Close in wording, no citation either way
- 2024Artifact Reduction in 3D and 4D Cone-beam Computed Tomography Images with Deep Learning -- A Review
- 2025Tooth-Diffusion: Guided 3D CBCT Synthesis with Fine-Grained Tooth Conditioning
- 2024Improving Cone-Beam CT Image Quality with Knowledge Distillation-Enhanced Diffusion Model in Imbalanced Data Settings
- 2025Conditional Diffusion Models for CT Image Synthesis from CBCT: A Systematic Review
- 2024HC3L-Diff: Hybrid conditional latent diffusion with high frequency enhancement for CBCT-to-CT synthesis
- 2026Cone-Beam CT Image Quality Enhancement Using A Latent Diffusion Model Trained with Simulated CBCT Artifacts
- 2026Field-of-View Extension in Dental Cone-Beam CT via Implicit Neural Representations and Diffusion Model-Based Refinement
- 2025Limited-Angle CBCT Reconstruction via Geometry-Integrated Cycle-domain Denoising Diffusion Probabilistic Models