SynthRAR: Ring Artifacts Reduction in CT with Unrolled Network and Synthetic Data Training
Not on the map. Why?
Abstract (arXiv)
Defective and inconsistent responses in CT detectors can cause ring and streak artifacts in the reconstructed images, making them unusable for clinical purposes. In recent years, several ring artifact reduction solutions have been proposed in the image domain or in the sinogram domain using supervised deep learning methods. However, these methods require dedicated datasets for training, leading to a high data collection cost. Furthermore, existing approaches focus exclusively on either image-space or sinogram-space correction, neglecting the intrinsic correlations from the forward operation of the CT geometry. Based on the theoretical analysis of non-ideal CT detector responses, the RAR problem is reformulated as an inverse problem by using an unrolled network, which considers non-ideal response together with linear forward-projection with CT geometry. Additionally, the intrinsic correlations of ring artifacts between the sinogram and image domains are leveraged through synthetic data derived from natural images, enabling the trained model to correct artifacts without requiring real-world clinical data. Extensive evaluations on diverse scanning geometries and anatomical regions demonstrate that the model trained on synthetic data consistently outperforms existing state-of-the-art methods.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 16 of its 30 references that are in the map. First posted on arXiv 12 Feb 2026.
Builds on
16 of 30 references.
References · 16
- 2014ImageNet Large Scale Visual Recognition Challengecited by 8,441
- 20163D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotationcited by 1,471
- 2022Simple Baselines for Image Restorationcited by 701
- 2017MoDL: Model Based Deep Learning Architecture for Inverse Problemscited by 384
- 2021SynthSeg: Segmentation of brain MRI scans of any contrast and resolution without retrainingcited by 235
- 2016Multivariate mixture model for myocardium segmentation combining multi-source imagescited by 133
- 2016A deep convolutional neural network using directional wavelets for low-dose X-ray CT reconstructioncited by 87
- 2020TorchRadon: Fast Differentiable Routines for Computed Tomographycited by 44
- 2021Self-Supervised Learning for MRI Reconstruction with a Parallel Network Training Frameworkcited by 26
- 2020An Adaptive Intelligence Algorithm for Undersampled Knee MRI Reconstructioncited by 19
- 2022Physics-/Model-Based and Data-Driven Methods for Low-Dose Computed Tomography: A surveycited by 14
- 2024Deep Rib Fracture Instance Segmentation and Classification from CT on the RibFrac Challengecited by 14
4 more
- 2024Ring Artifacts Removal Based on Implicit Neural Representation of Sinogram Datacited by 4
- 2024Unsupervised Multi-Parameter Inverse Solving for Reducing Ring Artifacts in 3D X-Ray CBCTcited by 3
- 2025Display Field-Of-View Agnostic Robust CT Kernel Synthesis Using Model-Based Deep Learningcited by 1
- 2026Low performing pixel correction in computed tomography with unrolled network and synthetic data trainingcited by 1
Built on by
Not cited yet.