mlsanityData to 14 Oct 2026

Blind Ultrasound Image Enhancement via Self-Supervised Physics-Guided Degradation Modeling

arXiv 2601.21856 ↗First posted 29 Jan 2026eess.IV cs.CV stat.MLcited by 1

Not on the map. Why?

Abstract (arXiv)

Ultrasound (US) interpretation is hampered by multiplicative speckle, acquisition blur from the point-spread function (PSF), and scanner- and operator-dependent artifacts. Supervised enhancement methods assume access to clean targets or known degradations; conditions rarely met in practice. We present a blind, self-supervised enhancement framework that jointly deconvolves and denoises B-mode images using a Swin Convolutional U-Net trained with a physics-guided degradation model. From each training frame, we extract rotated/cropped patches and synthesize inputs by (i) convolving with a Gaussian PSF surrogate and (ii) injecting noise via either spatial additive Gaussian noise or complex Fourier-domain perturbations that emulate phase/magnitude distortions. For US scans, clean-like targets are obtained via non-local low-rank (NLLR) denoising, removing the need for ground truth; for natural images, the originals serve as targets. Trained and validated on UDIAT~B, JNU-IFM, and XPIE Set-P, and evaluated additionally on a 700-image PSFHS test set, the method achieves the highest PSNR/SSIM across Gaussian and speckle noise levels, with margins that widen under stronger corruption. Relative to MSANN, Restormer, and DnCNN, it typically preserves an extra ~1--4,dB PSNR and 0.05--0.15 SSIM in heavy Gaussian noise, and ~2--5,dB PSNR and 0.05--0.20 SSIM under severe speckle. Controlled PSF studies show reduced FWHM and higher peak gradients, evidence of resolution recovery without edge erosion. Used as a plug-and-play preprocessor, it consistently boosts Dice for fetal head and pubic symphysis segmentation. Overall, the approach offers a practical, assumption-light path to robust US enhancement that generalizes across datasets, scanners, and degradation types.

Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). Builds on 10 of its 39 references that are in the map. First posted on arXiv 29 Jan 2026.

Builds on

10 of 39 references.

References · 10

  1. 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,713
  2. 2021Swin Transformer: Hierarchical Vision Transformer using Shifted Windowscited by 12,139
  3. 2016Gaussian Error Linear Units (GELUs)cited by 3,502
  4. 2016Beyond a Gaussian Denoiser: Residual Learning of Deep CNN for Image Denoisingcited by 1,358
  5. 2018Noise2Void - Learning Denoising from Single Noisy Imagescited by 364
  6. 2019Noise2Self: Blind Denoising by Self-Supervisioncited by 276
  7. 2022Practical Blind Image Denoising via Swin-Conv-UNet and Data Synthesiscited by 86
  8. 2016Medical image denoising using convolutional denoising autoencoderscited by 76
  9. 2023Fast and Accurate Estimation of Low-Rank Matrices from Noisy Measurements via Preconditioned Non-Convex Gradient Descentcited by 5
  10. 2019Deep Learning-based Universal Beamformer for Ultrasound Imagingcited by 4

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2026: 1.

1 paper.