mlsanityData to 14 Oct 2026

High Resolution Isotropic 3D Cine imaging with Automated Segmentation using Concatenated 2D Real-time Imaging and Deep Learning

arXiv 2506.22532 ↗First posted 27 Jun 2025eess.IV cs.CV cs.LGcited by 0

Not on the map. Why?

Abstract (arXiv)

Background: Conventional cardiovascular magnetic resonance (CMR) in paediatric and congenital heart disease uses 2D, breath-hold, balanced steady state free precession (bSSFP) cine imaging for assessment of function and cardiac-gated, respiratory-navigated, static 3D bSSFP whole-heart imaging for anatomical assessment. Our aim is to concatenate a stack 2D free-breathing real-time cines and use Deep Learning (DL) to create an isotropic a fully segmented 3D cine dataset from these images. Methods: Four DL models were trained on open-source data that performed: a) Interslice contrast correction; b) Interslice respiratory motion correction; c) Super-resolution (slice direction); and d) Segmentation of right and left atria and ventricles (RA, LA, RV, and LV), thoracic aorta (Ao) and pulmonary arteries (PA). In 10 patients undergoing routine cardiovascular examination, our method was validated on prospectively acquired sagittal stacks of real-time cine images. Quantitative metrics (ventricular volumes and vessel diameters) and image quality of the 3D cines were compared to conventional breath hold cine and whole heart imaging. Results: All real-time data were successfully transformed into 3D cines with a total post-processing time of <1 min in all cases. There were no significant biases in any LV or RV metrics with reasonable limits of agreement and correlation. There is also reasonable agreement for all vessel diameters, although there was a small but significant overestimation of RPA diameter. Conclusion: We have demonstrated the potential of creating a 3D-cine data from concatenated 2D real-time cine images using a series of DL models. Our method has short acquisition and reconstruction times with fully segmented data being available within 2 minutes. The good agreement with conventional imaging suggests that our method could help to significantly speed up CMR in clinical practice.

Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 4 of its 27 references that are in the map. First posted on arXiv 27 Jun 2025.

Builds on

4 of 27 references.

References · 4

  1. 2018A Deep Learning Framework for Unsupervised Affine and Deformable Image Registrationcited by 160
  2. 2018Real-time Cardiovascular MR with Spatio-temporal Artifact Suppression using Deep Learning - Proof of Concept in Congenital Heart Diseasecited by 18
  3. 2018A Comprehensive Approach for Learning-based Fully-Automated Inter-slice Motion Correction for Short-Axis Cine Cardiac MR Image Stackscited by 5
  4. 2019Rapid Whole-Heart CMR with Single Volume Super-resolutioncited by 4

Built on by

Not cited yet.