mlsanityData to 14 Oct 2026

Real-time Cardiovascular MR with Spatio-temporal Artifact Suppression using Deep Learning - Proof of Concept in Congenital Heart Disease

arXiv 1803.05192 ↗First posted 14 Mar 2018cs.CV cs.NEcited by 18

Not on the map. Why?

Abstract (arXiv)

PURPOSE: Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study we investigated the effect of different radial sampling patterns on the accuracy of a CNN. We also acquired actual real-time undersampled radial data in patients with congenital heart disease (CHD), and compare CNN reconstruction to Compressed Sensing (CS). METHODS: A 3D (2D plus time) CNN architecture was developed, and trained using 2276 gold-standard paired 3D data sets, with 14x radial undersampling. Four sampling schemes were tested, using 169 previously unseen 3D 'synthetic' test data sets. Actual real-time tiny Golden Angle (tGA) radial SSFP data was acquired in 10 new patients (122 3D data sets), and reconstructed using the 3D CNN as well as a CS algorithm; GRASP. RESULTS: Sampling pattern was shown to be important for image quality, and accurate visualisation of cardiac structures. For actual real-time data, overall reconstruction time with CNN (including creation of aliased images) was shown to be more than 5x faster than GRASP. Additionally, CNN image quality and accuracy of biventricular volumes was observed to be superior to GRASP for the same raw data. CONCLUSION: This paper has demonstrated the potential for the use of a 3D CNN for deep de-aliasing of real-time radial data, within the clinical setting. Clinical measures of ventricular volumes using real-time data with CNN reconstruction are not statistically significantly different from the gold-standard, cardiac gated, BH techniques.

Key facts. Cited by 18 papers in the map (data through 14 Oct 2026). First posted on arXiv 14 Mar 2018.

Builds on

No reference list yet.

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2021: 2; 2022: 3; 2023: 5; 2024: 3; 2025: 3; 2026: 2.

18 papers.

Sort:

By area:

  1. 2021Unsupervised MRI Reconstruction via Zero-Shot Learned Adversarial Transformerscited by 77
  2. 2023Uncertainty Estimation and Propagation in Accelerated MRI Reconstructioncited by 10
  3. 2021An End-To-End-Trainable Iterative Network Architecture for Accelerated Radial Multi-Coil 2D Cine MR Image Reconstructioncited by 7
  4. 2025End-to-End 4D Heart Mesh Recovery Across Full-Stack and Sparse Cardiac MRIcited by 6
  5. 2022A Projection-Based K-space Transformer Network for Undersampled Radial MRI Reconstruction with Limited Training Subjectscited by 4
  6. 2024Deep Separable Spatiotemporal Learning for Fast Dynamic Cardiac MRIcited by 4
  7. 2023HyperSLICE: HyperBand optimized Spiral for Low-latency Interactive Cardiac Examinationcited by 3
  8. 2022Data and Physics Driven Learning Models for Fast MRI -- Fundamentals and Methodologies from CNN, GAN to Attention and Transformerscited by 2
  9. 2023The Past, Current, and Future of Neonatal Intensive Care Units with Artificial Intelligencecited by 2
  10. 2023RED-PSM: Regularization by Denoising of Factorized Low Rank Models for Dynamic Imagingcited by 2
  11. 2023NoSENSE: Learned unrolled cardiac MRI reconstruction without explicit sensitivity mapscited by 1
  12. 2024Attention Incorporated Network for Sharing Low-rank, Image and K-space Information during MR Image Reconstruction to Achieve Single Breath-hold Cardiac Cine Imagingcited by 1
6 more
  1. 2025Deep Learning Assisted Outer Volume Removal for Highly-Accelerated Real-Time Dynamic MRIcited by 1
  2. 2022Artificial Intelligence-Based Image Reconstruction in Cardiac Magnetic Resonancecited by 0
  3. 2024Zero-shot Dynamic MRI Reconstruction with Global-to-local Diffusion Modelcited by 0
  4. 2025High Resolution Isotropic 3D Cine imaging with Automated Segmentation using Concatenated 2D Real-time Imaging and Deep Learningcited by 0
  5. 2026Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 Tcited by 0
  6. 2026Unsupervised Metal Artifact Reduction in Dental CBCT using Fine-tuned Cycle-Consistent Adversarial Networkscited by 0