mlsanityData to 14 Oct 2026

PET Tracer Separation Using Conditional Diffusion Transformer with Multi-latent Space Learning

arXiv 2506.16934 ↗First posted 20 Jun 2025eess.IV cs.CVcited by 0

On the map: Diffusion models → Medical imaging and segmentation

Abstract (arXiv)

In clinical practice, single-radiotracer positron emission tomography (PET) is commonly used for imaging. Although multi-tracer PET imaging can provide supplementary information of radiotracers that are sensitive to physiological function changes, enabling a more comprehensive characterization of physiological and pathological states, the gamma-photon pairs generated by positron annihilation reactions of different tracers in PET imaging have the same energy, making it difficult to distinguish the tracer signals. In this study, a multi-latent space guided texture conditional diffusion transformer model (MS-CDT) is proposed for PET tracer separation. To the best of our knowledge, this is the first attempt to use texture condition and multi-latent space for tracer separation in PET imaging. The proposed model integrates diffusion and transformer architectures into a unified optimization framework, with the novel addition of texture masks as conditional inputs to enhance image details. By leveraging multi-latent space prior derived from different tracers, the model captures multi-level feature representations, aiming to balance computational efficiency and detail preservation. The texture masks, serving as conditional guidance, help the model focus on salient structural patterns, thereby improving the extraction and utilization of fine-grained image textures. When combined with the diffusion transformer backbone, this conditioning mechanism contributes to more accurate and robust tracer separation. To evaluate its effectiveness, the proposed MS-CDT is compared with several advanced methods on two types of 3D PET datasets: brain and chest scans. Experimental results indicate that MS-CDT achieved competitive performance in terms of image quality and preservation of clinically relevant information. Code is available at: https://github.com/yqx7150/MS-CDT.

Key facts. No citing papers in the map yet (data through 14 Oct 2026). Placed in Medical imaging and segmentation, one of 14 directions in Diffusion models. First posted on arXiv 20 Jun 2025.

Builds on

0 of 0 references.

No references here yet.

Built on by

Not cited yet.

Similar, not cited

Close in wording, no citation either way

  1. 2024Diffusion Transformer Model With Compact Prior for Low-dose PET Reconstruction
  2. 2024st-DTPM: Spatial-Temporal Guided Diffusion Transformer Probabilistic Model for Delayed Scan PET Image Prediction
  3. 2025PET Image Reconstruction Using Deep Diffusion Image Prior
  4. 2025Supervised Diffusion-Model-Based PET Image Reconstruction
  5. 2024Volumetric Conditional Score-based Residual Diffusion Model for PET/MR Denoising
  6. 2025CT-Less Attenuation Correction Using Multiview Ensemble Conditional Diffusion Model on High-Resolution Uncorrected PET Images
  7. 2025Personalized MR-Informed Diffusion Models for 3D PET Image Reconstruction
  8. 2026Supervise-assisted Multi-modality Fusion Diffusion Model for PET Restoration