VORTEX: Physics-Driven Data Augmentations Using Consistency Training for Robust Accelerated MRI Reconstruction

arXiv 2111.02549 ↗First posted 3 Nov 2021eess.IV physics.med-phcited by 16

Not on the map. Why?

Abstract (arXiv)

Deep neural networks have enabled improved image quality and fast inference times for various inverse problems, including accelerated magnetic resonance imaging (MRI) reconstruction. However, such models require a large number of fully-sampled ground truth datasets, which are difficult to curate, and are sensitive to distribution drifts. In this work, we propose applying physics-driven data augmentations for consistency training that leverage our domain knowledge of the forward MRI data acquisition process and MRI physics to achieve improved label efficiency and robustness to clinically-relevant distribution drifts. Our approach, termed VORTEX, (1) demonstrates strong improvements over supervised baselines with and without data augmentation in robustness to signal-to-noise ratio change and motion corruption in data-limited regimes; (2) considerably outperforms state-of-the-art purely image-based data augmentation techniques and self-supervised reconstruction methods on both in-distribution and out-of-distribution data; and (3) enables composing heterogeneous image-based and physics-driven data augmentations. Our code is available at https://github.com/ad12/meddlr.

Key facts. Cited by 16 papers in the map (data through 7 Oct 2026). First posted on arXiv 3 Nov 2021.

Builds on

No reference list yet.

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2022: 4; 2023: 5; 2024: 2; 2025: 3; 2026: 2.