mlsanityData to 7 Oct 2026

Generative Models Improve Radiomics Performance in Different Tasks and Different Datasets: An Experimental Study

arXiv 2109.02252 ↗First posted 6 Sep 2021q-bio.QM cs.CV eess.IVcited by 0

Not on the map. Why?

Abstract (arXiv)

Radiomics is an active area of research focusing on high throughput feature extraction from medical images with a wide array of applications in clinical practice, such as clinical decision support in oncology. However, noise in low dose computed tomography (CT) scans can impair the accurate extraction of radiomic features. In this article, we investigate the possibility of using deep learning generative models to improve the performance of radiomics from low dose CTs. We used two datasets of low dose CT scans -NSCLC Radiogenomics and LIDC-IDRI - as test datasets for two tasks - pre-treatment survival prediction and lung cancer diagnosis. We used encoder-decoder networks and conditional generative adversarial networks (CGANs) trained in a previous study as generative models to transform low dose CT images into full dose CT images. Radiomic features extracted from the original and improved CT scans were used to build two classifiers - a support vector machine (SVM) and a deep attention based multiple instance learning model - for survival prediction and lung cancer diagnosis respectively. Finally, we compared the performance of the models derived from the original and improved CT scans. Encoder-decoder networks and CGANs improved the area under the curve (AUC) of survival prediction from 0.52 to 0.57 (p-value<0.01). On the other hand, Encoder-decoder network and CGAN can improve the AUC of lung cancer diagnosis from 0.84 to 0.88 and 0.89 respectively (p-value<0.01). Moreover, there are no statistically significant differences in improving AUC by using encoder-decoder network and CGAN (p-value=0.34) when networks trained at 75 and 100 epochs. Generative models can improve the performance of low dose CT-based radiomics in different tasks. Hence, denoising using generative models seems to be a necessary pre-processing step for calculating radiomic features from low dose CTs.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 11 of its 62 references that are in the map. First posted on arXiv 6 Sep 2021.

Builds on

11 of 62 references.

References · 11

  1. 2016Image-to-Image Translation with Conditional Adversarial Networkscited by 4,510
  2. 2018Attention-based Deep Multiple Instance Learningcited by 1,077
  3. 2019Deep Double Descent: Where Bigger Models and More Data Hurtcited by 667
  4. 2017Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)cited by 224
  5. 2017Low Dose CT Image Denoising Using a Generative Adversarial Network with Wasserstein Distance and Perceptual Losscited by 161
  6. 2020Double Trouble in Double Descent : Bias and Variance(s) in the Lazy Regimecited by 95
  7. 2018Brain Tumor Segmentation and Radiomics Survival Prediction: Contribution to the BRATS 2017 Challengecited by 56
  8. 20183D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning from a 2D Trained Networkcited by 47
  9. 2016Reliability of PET/CT shape and heterogeneity features in functional and morphological components of Non-Small Cell Lung Cancer tumors: a repeatability analysis in a prospective multi-center cohortcited by 3
  10. 2021Lung Cancer Diagnosis Using Deep Attention Based on Multiple Instance Learning and Radiomicscited by 3
  11. 2021Generative Models Improve Radiomics Reproducibility in Low Dose CTs: A Simulation Studycited by 3

Built on by

Not cited yet.