Generative Models Improve Radiomics Reproducibility in Low Dose CTs: A Simulation Study

arXiv 2104.15050 ↗First posted 30 Apr 2021q-bio.QM cs.LG eess.IVcited by 3

Not on the map. Why?

Abstract (arXiv)

Radiomics is an active area of research in medical image analysis, the low reproducibility of radiomics has limited its applicability to clinical practice. This issue is especially prominent when radiomic features are calculated from noisy images, such as low dose computed tomography (CT) scans. In this article, we investigate the possibility of improving the reproducibility of radiomic features calculated on noisy CTs by using generative models for denoising.One traditional denoising method - non-local means - and two generative models - encoder-decoder networks (EDN) and conditional generative adversarial networks (CGANs) - were selected as the test models. We added noise to the sinograms of full dose CTs to mimic low dose CTs with two different levels of noise: low-noise CT and high-noise CT. Models were trained on high-noise CTs and used to denoise low-noise CTs without re-training. We also test the performance of our model in real data, using dataset of same-day repeat low dose CTs to assess the reproducibility of radiomic features in denoised images. The EDN and the CGAN improved the concordance correlation coefficients (CCC) of radiomic features for low-noise images from 0.87 to 0.92 and for high-noise images from 0.68 to 0.92 respectively. Moreover, the EDN and the CGAN improved the test-retest reliability of radiomic features (mean CCC increased from 0.89 to 0.94) based on real low dose CTs. The results show that denoising using EDN and CGANs can improve the reproducibility of radiomic features calculated on noisy CTs. Moreover, images with different noise levels can be denoised to improve the reproducibility using these models without re-training, as long as the noise intensity is equal or lower than that in high-noise CTs. To the authors' knowledge, this is the first effort to improve the reproducibility of radiomic features calculated on low dose CT scans.

Key facts. Cited by 3 papers in the map (data through 7 Oct 2026). Builds on 14 of its 48 references that are in the map. First posted on arXiv 30 Apr 2021.

Builds on

14 of 48 references.

References · 14

  1. 2014Very Deep Convolutional Networks for Large-Scale Image Recognitioncited by 15,267
  2. 2014Fully Convolutional Networks for Semantic Segmentationcited by 4,845
  3. 2016Image-to-Image Translation with Conditional Adversarial Networkscited by 4,510
  4. 2016Perceptual Losses for Real-Time Style Transfer and Super-Resolutioncited by 2,678
  5. 2014Conditional Generative Adversarial Netscited by 2,152
  6. 2017Unpaired Image-to-Image Translation using Cycle-Consistent Adversarial Networkscited by 707
  7. 2018Generative Adversarial Network in Medical Imaging: A Reviewcited by 257
  8. 2017Low-Dose CT with a Residual Encoder-Decoder Convolutional Neural Network (RED-CNN)cited by 224
  9. 2017Low Dose CT Image Denoising Using a Generative Adversarial Network with Wasserstein Distance and Perceptual Losscited by 161
  10. 2018Photographic Text-to-Image Synthesis with a Hierarchically-nested Adversarial Networkcited by 64
  11. 20183D Convolutional Encoder-Decoder Network for Low-Dose CT via Transfer Learning from a 2D Trained Networkcited by 47
  12. 2019Quadratic Autoencoder (Q-AE) for Low-dose CT Denoisingcited by 35
2 more
  1. 2019Adversarially Approximated Autoencoder for Image Generation and Manipulationcited by 12
  2. 2016Reliability of PET/CT shape and heterogeneity features in functional and morphological components of Non-Small Cell Lung Cancer tumors: a repeatability analysis in a prospective multi-center cohortcited by 3

Built on by

Cited by year

Citing papers per year: 2021: 1; 2022: 0; 2023: 1; 2024: 0; 2025: 1.

3 papers.