An Accurate Non-accelerometer-based PPG Motion Artifact Removal Technique using CycleGAN
Not on the map. Why?
Abstract (arXiv)
A photoplethysmography (PPG) is an uncomplicated and inexpensive optical technique widely used in the healthcare domain to extract valuable health-related information, e.g., heart rate variability, blood pressure, and respiration rate. PPG signals can easily be collected continuously and remotely using portable wearable devices. However, these measuring devices are vulnerable to motion artifacts caused by daily life activities. The most common ways to eliminate motion artifacts use extra accelerometer sensors, which suffer from two limitations: i) high power consumption and ii) the need to integrate an accelerometer sensor in a wearable device (which is not required in certain wearables). This paper proposes a low-power non-accelerometer-based PPG motion artifacts removal method outperforming the accuracy of the existing methods. We use Cycle Generative Adversarial Network to reconstruct clean PPG signals from noisy PPG signals. Our novel machine-learning-based technique achieves 9.5 times improvement in motion artifact removal compared to the state-of-the-art without using extra sensors such as an accelerometer.
Key facts. Cited by 10 papers in the map (data through 7 Oct 2026). Builds on 10 of its 41 references that are in the map. First posted on arXiv 22 Jun 2021.
Builds on
10 of 41 references.
References · 10
- 2015Deep Residual Learning for Image Recognitioncited by 51,809
- 2016Image-to-Image Translation with Conditional Adversarial Networkscited by 4,510
- 2016Perceptual Losses for Real-Time Style Transfer and Super-Resolutioncited by 2,678
- 2016Photo-Realistic Single Image Super-Resolution Using a Generative Adversarial Networkcited by 1,898
- 2016Precomputed Real-Time Texture Synthesis with Markovian Generative Adversarial Networkscited by 192
- 2019Safe Linear Thompson Sampling with Side Informationcited by 37
- 2020Stage-wise Conservative Linear Banditscited by 28
- 2021An End-to-End and Accurate PPG-based Respiratory Rate Estimation Approach Using Cycle Generative Adversarial Networkscited by 11
- 2020Detection of COVID-19 Using Heart Rate and Blood Pressure: Lessons Learned from Patients with ARDScited by 5
- 2018Improving Photoplethysmographic Measurements under Motion Artifacts using Artificial Neural Network for Personal Healthcarecited by 4
Built on by
Citing papers per year: 2022: 1; 2023: 2; 2024: 2; 2025: 4; 2026: 1.
10 papers.
- 2024PaPaGei: Open Foundation Models for Optical Physiological Signalscited by 64
- 2023Deep Generative Models for Physiological Signals: A Systematic Literature Reviewcited by 7
- 2023Tiny-PPG: A Lightweight Deep Neural Network for Real-Time Detection of Motion Artifacts in Photoplethysmogram Signals on Edge Devicescited by 4
- 2024SQUWA: Signal Quality Aware DNN Architecture for Enhanced Accuracy in Atrial Fibrillation Detection from Noisy PPG Signalscited by 4
- 2022Novel Blood Pressure Waveform Reconstruction from Photoplethysmography using Cycle Generative Adversarial Networkscited by 2
- 2026PulseLM: A Foundation Dataset and Benchmark for PPG-Text Learningcited by 2
- 2025Joint Attention Mechanism Learning to Facilitate Opto-physiological Monitoring during Physical Activitycited by 0
- 2025TAU: Modeling Temporal Consistency Through Temporal Attentive U-Net for PPG Peak Detectioncited by 0
- 2025Finger-to-Chest Style Transfer-assisted Deep Learning Method For Photoplethysmogram Waveform Restoration with Timing Preservationcited by 0
- 2025Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contactcited by 0
- 2026PulseLM: A Foundation Dataset and Benchmark for PPG-Text Learning10 Feb 2026
- 2025Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact3 Apr 2025
- 2025TAU: Modeling Temporal Consistency Through Temporal Attentive U-Net for PPG Peak Detection13 Mar 2025
- 2025Finger-to-Chest Style Transfer-assisted Deep Learning Method For Photoplethysmogram Waveform Restoration with Timing Preservation11 Mar 2025
- 2025Joint Attention Mechanism Learning to Facilitate Opto-physiological Monitoring during Physical Activity13 Feb 2025
- 2024PaPaGei: Open Foundation Models for Optical Physiological Signals27 Oct 2024
- 2024SQUWA: Signal Quality Aware DNN Architecture for Enhanced Accuracy in Atrial Fibrillation Detection from Noisy PPG Signals15 Apr 2024
- 2023Deep Generative Models for Physiological Signals: A Systematic Literature Review12 Jul 2023
- 2023Tiny-PPG: A Lightweight Deep Neural Network for Real-Time Detection of Motion Artifacts in Photoplethysmogram Signals on Edge Devices5 May 2023
- 2022Novel Blood Pressure Waveform Reconstruction from Photoplethysmography using Cycle Generative Adversarial Networks24 Jan 2022