Reliable Physiological Monitoring on the Wrist Using Generative Deep Learning to Address Poor Skin-Sensor Contact
Not on the map. Why?
Abstract (arXiv)
Photoplethysmography (PPG) is a widely adopted, non-invasive technique for monitoring cardiovascular health and physiological parameters in both consumer and clinical settings. While motion artifacts in dynamic environments have been extensively studied, suboptimal skin-sensor contact in sedentary conditions - a critical yet underexplored issue - can distort PPG waveform morphology, leading to the loss or misalignment of key features and compromising sensing accuracy. In this work, we propose CP-PPG, a novel framework that transforms Contact Pressure-distorted PPG signals into high-fidelity waveforms with ideal morphology. CP-PPG integrates a custom data collection protocol, a carefully designed signal processing pipeline, and a novel deep adversarial model trained with a custom PPG-aware loss function. We validated CP-PPG through comprehensive evaluations, including 1) morphology transformation performance on our self-collected dataset, 2) downstream physiological monitoring performance on public datasets, and 3) in-the-wild study. Extensive experiments demonstrate substantial and consistent improvements in signal fidelity (Mean Absolute Error: 0.09, 40% improvement over the original signal) as well as downstream performance across all evaluations in Heart Rate (HR), Heart Rate Variability (HRV), Respiration Rate (RR), and Blood Pressure (BP) estimation (on average, 21% improvement in HR; 41-46% in HRV; 6% in RR; and 4-5% in BP). These findings highlight the critical importance of addressing skin-sensor contact issues to enhance the reliability and effectiveness of PPG-based physiological monitoring. CP-PPG thus holds significant potential to improve the accuracy of wearable health technologies in clinical and consumer applications.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 7 of its 84 references that are in the map. First posted on arXiv 3 Apr 2025.
Builds on
7 of 84 references.
References · 7
- 2016Image-to-Image Translation with Conditional Adversarial Networkscited by 4,527
- 2014Learning Phrase Representations using RNN Encoder-Decoder for Statistical Machine Translationcited by 4,057
- 2015Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstructioncited by 16
- 2020Estimating Blood Pressure from Photoplethysmogram Signal and Demographic Features using Machine Learning Techniquescited by 13
- 2021An Accurate Non-accelerometer-based PPG Motion Artifact Removal Technique using CycleGANcited by 10
- 2021MAUS: A Dataset for Mental Workload Assessmenton N-back Task Using Wearable Sensorcited by 7
- 2023Tiny-PPG: A Lightweight Deep Neural Network for Real-Time Detection of Motion Artifacts in Photoplethysmogram Signals on Edge Devicescited by 4
Built on by
Not cited yet.