Opto-physiological monitoring including photoplethysmography (PPG) provides non-invasive cardiac and respiratory measurements, yet motion artefacts (MAs) during physical activity degrade its signal quality and downstream estimation concurrently. An attention-mechanism-based generative adversarial network (AM-GAN) was proposed to model motion artefacts and mitigate their impact on raw PPG signals. The AM-GAN learns how to transform motion-affected PPG into artefact-reduced waveforms to align with triaxial acceleration signals corresponding to artefact components gained from a triaxial accelerometer. The AM-GAN has been validated across four experimental protocols with 43 participants performing activities from low to high intensity (6--12km/h). With the public datasets, the AM-GAN achieves mean absolute error (MAE) for heart rate (HR) of 1.81 beats/min on IEEE-SPC and 3.86 beats/min on PPGDalia. On the in-house LU dataset, it shows the MAEs < 1.37 beats/min for HR and 2.49 breaths/min for respiratory rate (RR). A further in-house C2 dataset with three oxygen levels (16%, 18%, and 21%) was applied in the AM-GAN to attain a MAE of 1.65% for SpO2. The outcome demonstrates that the AM-GAN offers a robust and reliable physiological estimation under various intensities of physical activity.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 10 of its 32 references that are in the map. First posted on arXiv 13 Feb 2025.
Builds on
10 of 32 references.
References · 10
- 2017Attention Is All You Needcited by 59,932
- 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,604
- 2014TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercisecited by 40
- 2020CardioGAN: Attentive Generative Adversarial Network with Dual Discriminators for Synthesis of ECG from PPGcited by 34
- 2015Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstructioncited by 16
- 2022Q-PPG: Energy-Efficient PPG-based Heart Rate Monitoring on Wearable Devicescited by 14
- 2021An Accurate Non-accelerometer-based PPG Motion Artifact Removal Technique using CycleGANcited by 10
- 2024KID-PPG: Knowledge Informed Deep Learning for Extracting Heart Rate from a Smartwatchcited by 7
- 2022Robust and Energy-efficient PPG-based Heart-Rate Monitoringcited by 6
- 2018SPECMAR: Fast Heart Rate Estimation from PPG Signal using a Modified Spectral Subtraction Scheme with Composite Motion Artifacts Reference Generationcited by 1
Built on by