mlsanityData to 14 Oct 2026

Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 T

arXiv 2605.26127 ↗First posted 18 May 2026physics.med-ph cs.LG eess.IVcited by 0

Not on the map. Why?

Abstract (arXiv)

Purpose: Real-time (RT) bSSFP MRI enables fast free-breathing cardiovascular imaging but requires 10-16 slices for functional assessment, resulting in prolonged scan times. Simultaneous multi-slice (SMS) imaging can reduce acquisition time but when combined with non-Cartesian trajectories, it relies on iterative reconstructions that preclude online use. This study investigates deep artifact suppression to facilitate rapid, online reconstruction of RT-SMS. Methods: A spiral bSSFP SMS RT sequence with two simultaneously acquired slices was implemented at 1.5 T. Reconstruction used slice separation in k-space, followed by deep artifact suppression in image space using a 3D U-Net. Ten healthy volunteers were imaged. RT-SMS image quality and reconstruction time were compared between deep artifact suppression and compressed sensing (CS) reconstructions. Left (LV) and right (RV) ventricular volumes at end diastole (EDV) and end systole (ESV) and LV mass (LVM) were compared between RT-SMS with deep artifact suppression and reference-standard breath-hold (BH) imaging. Results: The RT-SMS acquisition was ~13x faster than BH imaging (15 s vs 3 min 15 s). RT-SMS reconstruction using deep artifact suppression was ~50x faster than CS (30 s vs 24 min 55 s). Deep artifact suppression consistently outperformed CS in quantitative and qualitative image quality (p<0.001). Functional agreement between BH and RT-SMS with deep artifact suppression was good (LVEDV: -7.5 +/- 6.8 ml, LVESV: -0.9 +/- 4.2 ml, RVEDV: -6.4 +/- 8.4 ml, RVESV: 0.2 +/- 10.7 ml, LVM: -10.3 +/- 11.0 g). Conclusion: Online deep artifact suppression reconstruction for RT-SMS bSSFP CMR enables free-breathing short-axis coverage with a substantial reduction in acquisition and reconstruction time while maintaining diagnostic image quality.

Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 4 of its 28 references that are in the map. First posted on arXiv 18 May 2026.

Builds on

4 of 28 references.

References · 4

  1. 2014Adam: A Method for Stochastic Optimizationcited by 37,240
  2. 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,713
  3. 2020OCMR (v1.0)--Open-Access Multi-Coil k-Space Dataset for Cardiovascular Magnetic Resonance Imagingcited by 36
  4. 2018Real-time Cardiovascular MR with Spatio-temporal Artifact Suppression using Deep Learning - Proof of Concept in Congenital Heart Diseasecited by 18

Built on by

Not cited yet.