mlsanityData to 7 Oct 2026

Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognition

arXiv 2610.01692 ↗First posted 1 Oct 2026cs.LG eess.SPcited by 0

Not on the map. Why?

Abstract (arXiv)

Wrist electrodermal activity (EDA) differs in amplitude from one person to the next, so affect-recognition models normalize their input before classification. Studies that test such models on held-out subjects seldom report where the normalization statistics come from, yet statistics computed from the held-out subject's own recording give the model information that a device does not have when it is first worn. We asked how this choice alters the measured benefit of pretraining. A compact convolutional network, SAFE-EDA, was pretrained on expert artifact annotations from 43 subjects and compared with the same network trained from scratch on the Wearable Stress and Affect Detection (WESAD) dataset (15 subjects, leave-one-subject-out), with two normalization sources crossed with four window hops. When the statistics came only from training subjects, pretraining raised macro-F1 by 0.078 to 0.227; when they came from the held-out user's full recording, the gain fell to between 0.020 and 0.050 and was no longer significant. Artifact supervision was far more useful than self-supervised pretraining on the same recordings (0.078 versus 0.008). Across 13 configurations in two datasets, the pretrained network was better in 12, but on the second dataset (26 subjects) per-user normalization increased the gain instead of reducing it, so the interaction depends on the data. Only five of 50 published WESAD studies state which data were used for normalization. Reporting this choice is necessary to separate first-use performance from performance after calibration.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 11 of its 77 references that are in the map. First posted on arXiv 1 Oct 2026.

Builds on

11 of 77 references.

References · 11

  1. 2020Improving Reproducibility in Machine Learning Research (A Report from the NeurIPS 2019 Reproducibility Program)cited by 318
  2. 2023A Comparison of Personalized and Generalized Approaches to Emotion Recognition Using Consumer Wearable Devices: Machine Learning Studycited by 7
  3. 2022Ensemble Machine Learning Model Trained on a New Synthesized Dataset Generalizes Well for Stress Prediction Using Wearable Devicescited by 6
  4. 2017Unsupervised Motion Artifact Detection in Wrist-Measured Electrodermal Activity Datacited by 3
  5. 2024Stress Assessment with Convolutional Neural Network Using PPG Signalscited by 3
  6. 2022SELF-CARE: Selective Fusion with Context-Aware Low-Power Edge Computing for Stress Detectioncited by 2
  7. 2023Stress Detection using Context-Aware Sensor Fusion from Wearable Devicescited by 2
  8. 2024Real-Time Stress Detection via Photoplethysmogram Signals: Implementation of a Combined Continuous Wavelet Transform and Convolutional Neural Network on Resource-Constrained Microcontrollerscited by 2
  9. 2025Cross-Modality Investigation on WESAD Stress Classificationcited by 2
  10. 2021A Preliminary Study on Automatic Motion Artifacts Detection in Electrodermal Activity Data Using Machine Learningcited by 1
  11. 2026Stress Classification from ECG Signals Using Vision Transformercited by 1

Built on by

Not cited yet.