Real-Time Stress Detection via Photoplethysmogram Signals: Implementation of a Combined Continuous Wavelet Transform and Convolutional Neural Network on Resource-Constrained Microcontrollers
Not on the map. Why?
Abstract (arXiv)
This paper introduces a robust stress detection system utilizing a Convolutional Neural Network (CNN) designed for the analysis of Photoplethysmogram (PPG) signals. Employing the WESAD dataset, we applied Continuous Wavelet Transform (CWT) to extract informative features from wrist PPG signals, demonstrating enhanced stress detection and learning compared to conventional techniques. Notably, the CNN achieved an impressive accuracy of 93.7% after five epochs, post-implementation on a resource-constrained microcontroller. The optimization process, including pruning and Post-Train Quantization, was crucial to reduce the model size to 1.6 megabytes, overcoming the microcontroller's limited resources of 2 megabytes of Flash memory and 512 kilobytes of RAM. This optimized model not only addresses resource constraints but also outperforms traditional signal processing methods, positioning it as a promising solution for real-time stress monitoring on wearable devices.
Key facts. Cited by 2 papers in the map (data through 14 Oct 2026). Builds on 3 of its 20 references that are in the map. First posted on arXiv 14 Oct 2024.
Builds on
3 of 20 references.
References · 3
- 2020GSR Analysis for Stress: Development and Validation of an Open Source Tool for Noisy Naturalistic GSR Datacited by 8
- 2021Feature Augmented Hybrid CNN for Stress Recognition Using Wrist-based Photoplethysmography Sensorcited by 6
- 2024Stress Detection Using PPG Signal and Combined Deep CNN-MLP Networkcited by 4
Built on by
Citing papers per year: 2025: 1; 2026: 1.
2 papers.
- 2025Multimodal signal fusion for stress detection using deep neural networks: a novel approach for converting 1D signals to unified 2D imagescited by 0
- 2026Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognitioncited by 0
- 2026Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognition1 Oct 2026
- 2025Multimodal signal fusion for stress detection using deep neural networks: a novel approach for converting 1D signals to unified 2D images17 Sep 2025
Similar, not cited
Close in wording, no citation either way
- 2026PPG-Based Affect Recognition with Long-Range Deep Models: A Measurement-Driven Comparison of CNN, Transformer, and Mamba Architectures
- 2025Robust Photoplethysmography Signal Denoising via Mamba Networks
- 2022Q-PPG: Energy-Efficient PPG-based Heart Rate Monitoring on Wearable Devices
- 2024PhysMamba: Efficient Remote Physiological Measurement with SlowFast Temporal Difference Mamba
- 2024RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement
- 2024Enhancing Performance and User Engagement in Everyday Stress Monitoring: A Context-Aware Active Reinforcement Learning Approach
- 2025PPG-Distill: Efficient Photoplethysmography Signals Analysis via Foundation Model Distillation
- 2025Towards Characterizing Knowledge Distillation of PPG Heart Rate Estimation Models