mlsanityData to 7 Oct 2026

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

arXiv 2609.23924 ↗First posted 20 Sep 2026cs.LG q-bio.NCcited by 0

Not on the map. Why?

Abstract (arXiv)

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 13 of its 28 references that are in the map. First posted on arXiv 20 Sep 2026.

Builds on

13 of 28 references.

References · 13

  1. 2017On Calibration of Modern Neural Networkscited by 4,860
  2. 2016EEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfacescited by 616
  3. 2024Large Brain Model for Learning Generic Representations with Tremendous EEG Data in BCIcited by 311
  4. 2024CBraMod: A Criss-Cross Brain Foundation Model for EEG Decodingcited by 188
  5. 2018MOABB: Trustworthy algorithm benchmarking for BCIscited by 80
  6. 2024The largest EEG-based BCI reproducibility study for open science: the MOABB benchmarkcited by 28
  7. 2025EEG-FM-Bench: A Comprehensive Benchmark for the Systematic Evaluation and Diagnostic Analyses of EEG Foundation Modelscited by 21
  8. 2025AdaBrain-Bench: Benchmarking Brain Foundation Models for Brain-Computer Interface Applicationscited by 16
  9. 2026NeuralBench: A Unifying Framework to Benchmark NeuroAI Modelscited by 13
  10. 2026Brain4FMs: A Benchmark of Foundation Models for Electrical Brain Signalcited by 5
  11. 2026NeuroAtlas: Benchmarking Foundation Models for Clinical EEG and Brain-Computer Interfacescited by 5
  12. 2026OmniEEG-Bench: A Standardized Evaluation Benchmark for EEG Foundation Modelscited by 5
1 more
  1. 2026A Negative-Control Protocol for Clinical EEG Foundation-Model Benchmarks: Dataset Identity and External-Cohort Stress Testingcited by 3

Built on by

Not cited yet.