mlsanityData to 7 Oct 2026

Reliable Benchmarking of Artifact Detection in Computational Pathology: A Reproducibility and Uncertainty Analysis

arXiv 2608.30835 ↗First posted 31 Aug 2026cs.CV cs.AIcited by 1

Not on the map. Why?

Abstract (arXiv)

Background and Objective: Quality control is a prerequisite for whole-slide image analysis, yet the benchmarks on which quality-control methods are compared share four properties that make their reported differences hard to interpret: few independent slides, annotation concentrated in a minority of them, pooled ratio metrics with no closed-form standard error, and a single inherited train/test partition. We propose a reliability protocol for such benchmarks. Methods: The protocol quantifies four sources of variability - test-set sampling, training stochasticity, partition composition, and undocumented preprocessing - a claim is reportable only if it survives all four; three of the four cost minutes of compute. We apply it to an independent reconstruction of a published diffusion-based artifact detector, evaluated on the original 24-slide partition and against a supervised baseline. Results: The method's central mechanism reproduces: the auxiliary contrastive term improves pooled F1 from 0.673 to 0.688 and replicates under a second seed (+0.0156, p = 0.031; +0.0190, p = 0.005), although it acts on pen marking rather than the artifact types cited to motivate it. Its comparative claims do not: differences between design variants, and against the supervised baseline, fall inside the uncertainty of the evaluation. Four of 24 slides carry 70% of scored annotated pixels, giving an effective sample size of 6.2, and the inherited partition sits at the 7th percentile. An unreported tissue-restriction step excludes 41.4% of out-of-focus annotation against 2.6% of air bubble; such a gate is confounded with blur by construction. Conclusions: Small-cohort benchmarks support far weaker conclusions than current reporting implies. The four checks are cheap enough to accompany any evaluation on such a resource and separate reproducible effects from differences the evaluation cannot resolve.

Key facts. Cited by 1 paper in the map (data through 7 Oct 2026). Builds on 12 of its 48 references that are in the map. First posted on arXiv 31 Aug 2026.

Builds on

12 of 48 references.

References · 12

  1. 2020Denoising Diffusion Probabilistic Modelscited by 20,851
  2. 2021High-Resolution Image Synthesis with Latent Diffusion Modelscited by 18,694
  3. 2021Accounting for Variance in Machine Learning Benchmarkscited by 195
  4. 2022Denoising diffusion models for out-of-distribution detectioncited by 102
  5. 2020A Multi-resolution Model for Histopathology Image Classification and Localization with Multiple Instance Learningcited by 35
  6. 2024Efficient Quality Control of Whole Slide Pathology Images with Human-in-the-loop Trainingcited by 12
  7. 2025PixCell: A generative foundation model for digital histopathology imagescited by 11
  8. 2024Equipping Computational Pathology Systems with Artifact Processing Pipelines: A Showcase for Computation and Performance Trade-offscited by 9
  9. 2024FAST: A Dual-tier Few-Shot Learning Paradigm for Whole Slide Image Classificationcited by 8
  10. 2022Reproducibility in machine learning for medical imagingcited by 5
  11. 2023Rapid Artefact Removal and H&E-Stained Tissue Segmentationcited by 2
  12. 2025Integration of nested cross-validation, automated hyperparameter optimization, high-performance computing to reduce and quantify the variance of test performance estimation of deep learning modelscited by 1

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2026: 1.

1 paper.