PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

arXiv 2607.20136 ↗First posted 22 Jul 2026physics.med-ph cs.AIcited by 0

Not on the map. Why?

Abstract (arXiv)

Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 16 of its 71 references that are in the map. First posted on arXiv 22 Jul 2026.

Builds on

16 of 71 references.

References · 16

  1. 20233D Gaussian Splatting for Real-Time Radiance Field Renderingcited by 6,141
  2. 2022Instant Neural Graphics Primitives with a Multiresolution Hash Encodingcited by 3,698
  3. 2021Convex optimizationcited by 2,479
  4. 2020Implicit Neural Representations with Periodic Activation Functionscited by 2,214
  5. 2020Fourier Features Let Networks Learn High Frequency Functions in Low Dimensional Domainscited by 2,170
  6. 2021IREM: High-Resolution Magnetic Resonance (MR) Image Reconstruction via Implicit Neural Representationcited by 42
  7. 2024Where Do We Stand with Implicit Neural Representations? A Technical and Performance Surveycited by 41
  8. 2023Single-subject Multi-contrast MRI Super-resolution via Implicit Neural Representationscited by 32
  9. 2022SVoRT: Iterative Transformer for Slice-to-Volume Registration in Fetal Brain MRIcited by 26
  10. 2023Fetal-BET: Brain Extraction Tool for Fetal MRIcited by 7
  11. 2025Fast and Explicit: Slice-to-Volume Reconstruction via 3D Gaussian Primitives with Analytic Point Spread Function Modelingcited by 5
  12. 2023FetMRQC: a robust quality control system for multi-centric fetal brain MRIcited by 4
4 more
  1. 2025Meta-learning Slice-to-Volume Reconstruction in Fetal Brain MRI using Implicit Neural Representationscited by 4
  2. 2020T2 Mapping from Super-Resolution-Reconstructed Clinical Fast Spin Echo Magnetic Resonance Acquisitionscited by 3
  3. 2024Evaluating Synthetic Data Generation for Domain Generalization in Fetal Brain MRI Segmentationcited by 3
  4. 2025Physics-Informed Joint Multi-TE Super-Resolution with Implicit Neural Representation for Robust Fetal T2 Mappingcited by 1

Built on by

Not cited yet.