mlsanityData to 14 Oct 2026

RadSEM: A Finding-by-Finding Metric for Clinical Consistency in Radiology Reports

arXiv 2606.17062 ↗First posted 3 Jun 2026q-bio.QM cs.LGcited by 3

Not on the map. Why?

Abstract (arXiv)

Radiology report evaluation must distinguish clinical compatibility from surface similarity, because negation, laterality, or normal-abnormal polarity can reverse a finding. We propose RadSEM (Radiology Sentence-Level Evaluation Metric), a constrained LLM-assisted metric for reference-based evaluation of radiology Findings. RadSEM rewrites reference and generated reports into ordered atomic finding sentences, each expressing one site-finding proposition. It then performs contradiction-constrained many-to-many matching: incompatible pairs such as "effusion" and "no effusion" receive no credit, while compatible granularity differences can receive partial credit. A deterministic stage weights pairs by part-whole and abnormal-detail relationships, counts unmatched findings, and produces an abnormal-focused weighted F1 score. Thus, the LLM supports structured rewriting and local alignment rather than acting as an opaque judge. We evaluate RadSEM with SSREE, a controlled monotonicity stress test built from 2,448 de-identified reports expanded into five graded corruption levels. RadSEM achieves Kendall tau_b of 0.957, all-pairs concordance of 97.8%, adjacent concordance of 95.0%, and strict five-level ordering for 81.9% of reports, outperforming radiology-specific and general text metrics while avoiding the failure in which polarity-inverted reports regain lexical overlap. On the same SSREE set, RadSEM outperforms the Ref-anchored RadSEM-Alt policy, improving adjacent concordance from 90.7% to 95.0% and strict ordering from 67.2% to 81.9%. On a 599-triplet synonym/antonym subset, RadSEM prefers synonyms in 597 cases (99.67%). These results suggest that explicit finding units, contradiction-aware matching, and abnormal-focused deterministic scoring make report scoring more interpretable and sensitive to clinically meaningful errors. Code is available at https://github.com/jdh-algo/RadSEM.

Key facts. Cited by 3 papers in the map (data through 14 Oct 2026). Builds on 10 of its 14 references that are in the map. First posted on arXiv 3 Jun 2026.

Builds on

10 of 14 references.

References · 10

  1. 2014CIDEr: Consensus-based Image Description Evaluationcited by 2,046
  2. 2021RadGraph: Extracting Clinical Entities and Relations from Radiology Reportscited by 319
  3. 2024GREEN: Generative Radiology Report Evaluation and Error Notationcited by 128
  4. 2024RaTEScore: A Metric for Radiology Report Generationcited by 65
  5. 2020Chest X-ray Report Generation through Fine-Grained Label Learningcited by 26
  6. 2025MedBench v4: A Robust and Scalable Benchmark for Evaluating Chinese Medical Language Models, Multimodal Models, and Intelligent Agentscited by 8
  7. 2020Extracting and Learning Fine-Grained Labels from Chest Radiographscited by 5
  8. 2024Evaluating Automated Radiology Report Quality through Fine-Grained Phrasal Grounding of Clinical Findingscited by 3
  9. 2025Benchmarking Chinese Medical LLMs: A Medbench-based Analysis of Performance Gaps and Hierarchical Optimization Strategiescited by 2
  10. 2025Phrase-grounded Fact-checking for Automatically Generated Chest X-ray Reportscited by 2

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2026: 3.

3 papers.