Beyond Accuracy: Robustness, Interpretability and Expressiveness of EEG Foundation Models
Not on the map. Why?
Abstract (arXiv)
EEG foundation models (EEG-FMs) have been evaluated predominantly on clean, in-distribution accuracy, demonstrating modest gains over supervised baselines and weak frozen representations. This study examines whether these conclusions hold beyond clean accuracy by evaluating six EEG-FMs and a supervised baseline across ten datasets along three layers of analysis: (i) Robustness: we apply test-time perturbations including additive noise, random and region-based channel dropout and region-specific noise injection. Our analyses show that no single model dominates all failure modes. The most noise-robust model is among the most fragile under channel dropout and much of the dropout fragility disappears when channels are removed rather than zero-padded. (ii) Interpretability: using attribution methods in EEG-FMs, we show that models broadly concentrate relevance on task-appropriate brain regions consistent with known neurophysiology. (iii) Expressiveness: we demonstrate that the poor head-only performance previously attributed to low-quality pre-trained representations is largely explained by the pooling strategy and that EEG-FMs possess sufficient representational capacity when their token-level embeddings are preserved. Furthermore, with block-wise probing and attention analysis we show that late blocks are repurposed during fine-tuning, while early blocks already hold task-related information. Our results show that conclusions about EEG-FMs depend on evaluation choices and we recommend that future evaluation of EEG-FMs should report robustness per perturbation type, produce attribution maps and examine multiple pooling strategies.
Key facts. Cited by 3 papers in the map (data through 7 Oct 2026). Builds on 19 of its 54 references that are in the map. First posted on arXiv 17 May 2026.
Builds on
19 of 54 references.
References · 19
- 2020Language Models are Few-Shot Learnerscited by 32,199
- 2016Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localizationcited by 6,690
- 2017Learning Important Features Through Propagating Activation Differencescited by 1,454
- 2017SmoothGrad: removing noise by adding noisecited by 1,097
- 2020Quantifying Attention Flow in Transformerscited by 759
- 2020Towards Faithfully Interpretable NLP Systems: How should we define and evaluate faithfulness?cited by 590
- 2021Generic Attention-model Explainability for Interpreting Bi-Modal and Encoder-Decoder Transformerscited by 316
- 2024Large Brain Model for Learning Generic Representations with Tremendous EEG Data in BCIcited by 311
- 2024CBraMod: A Criss-Cross Brain Foundation Model for EEG Decodingcited by 188
- 2019The Bottom-up Evolution of Representations in the Transformer: A Study with Machine Translation and Language Modeling Objectivescited by 139
- 2024AttnLRP: Attention-Aware Layer-Wise Relevance Propagation for Transformerscited by 116
- 2020What Happens To BERT Embeddings During Fine-tuning?cited by 113
7 more
- 2020Subject-Aware Contrastive Learning for Biosignalscited by 75
- 2025REVE: A Foundation Model for EEG -- Adapting to Any Setup with Large-Scale Pretraining on 25,000 Subjectscited by 70
- 2025EEG Foundation Models: A Critical Review of Current Progress and Future Directionscited by 30
- 2025BrainOmni: A Brain Foundation Model for Unified EEG and MEG Signalscited by 25
- 2025Are Large Brainwave Foundation Models Capable Yet? Insights from Fine-tuningcited by 15
- 2023Interpretable and Robust AI in EEG Systems: A Surveycited by 10
- 2025Unmute the Patch Tokens: Rethinking Probing in Multi-Label Audio Classificationcited by 7
Built on by
Citing papers per year: 2026: 3.
3 papers.
- 2026A Negative-Control Protocol for Clinical EEG Foundation-Model Benchmarks: Dataset Identity and External-Cohort Stress Testingcited by 3
- 2026Cross-Cohort Spectral-Temporal Dissociation in Frozen EEG Foundation-Model Representationscited by 1
- 2026Representational and Functional Robustness to Electrode Montages in EEG Foundation Modelscited by 0
- 2026Representational and Functional Robustness to Electrode Montages in EEG Foundation Models28 Sep 2026
- 2026A Negative-Control Protocol for Clinical EEG Foundation-Model Benchmarks: Dataset Identity and External-Cohort Stress Testing27 Jul 2026
- 2026Cross-Cohort Spectral-Temporal Dissociation in Frozen EEG Foundation-Model Representations23 Jul 2026