Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)

arXiv 2604.06482 ↗First posted 7 Apr 2026physics.med-ph cs.LGcited by 1

Not on the map. Why?

Abstract (arXiv)

Time-resolved volumetric MR imaging that reconstructs a 3D MRI within sub-seconds to resolve deformable motion is essential for motion-adaptive radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a spatiotemporal Gaussian representation-based framework (DREME-GSMR), which enables time-resolved dynamic MRI reconstruction from a pre-treatment 3D MR scan without any prior anatomical/motion model. DREME-GSMR represents a reference MRI volume and a corresponding low-rank motion model (as motion-basis components) using 3D Gaussians, and incorporates a dual-path MLP/CNN motion encoder to estimate temporal motion coefficients of the motion model from raw k-space-derived signals. Furthermore, using the solved motion model, DREME-GSMR can infer motion coefficients directly from new online k-space data, allowing subsequent intra-treatment volumetric MR imaging and motion tracking (real-time imaging). A motion-augmentation strategy is further introduced to improve robustness to unseen motion patterns during real-time imaging. DREME-GSMR was evaluated on the XCAT digital phantom, a physical motion phantom, and MR-LINAC datasets acquired from 6 healthy volunteers and 20 patients (with independent sequential scans for cross-evaluation). DREME-GSMR reconstructs MRIs of a ~400ms temporal resolution, with an inference time of ~10ms/volume. In XCAT experiments, DREME-GSMR achieved mean(s.d.) SSIM, tumor center-of-mass-error(COME), and DSC of 0.92(0.01)/0.91(0.02), 0.50(0.15)/0.65(0.19) mm, and 0.92(0.02)/0.92(0.03) for dynamic reconstruction/real-time imaging. For the physical phantom, the mean target COME was 1.19(0.94)/1.40(1.15) mm for dynamic/real-time imaging, while for volunteers and patients, the mean liver COME for real-time imaging was 1.31(0.82) and 0.96(0.64) mm, respectively.

Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). Builds on 12 of its 70 references that are in the map. First posted on arXiv 7 Apr 2026.

Builds on

12 of 70 references.

References · 12

  1. 2014Adam: A Method for Stochastic Optimizationcited by 37,240
  2. 2019PyTorch: An Imperative Style, High-Performance Deep Learning Librarycited by 20,305
  3. 2021NeRP: Implicit Neural Representation Learning with Prior Embedding for Sparsely Sampled Image Reconstructioncited by 146
  4. 2024FlashGS: Efficient 3D Gaussian Splatting for Large-scale and High-resolution Renderingcited by 88
  5. 2024R2-Gaussian: Rectifying Radiative Gaussian Splatting for Tomographic Reconstructioncited by 67
  6. 2023A survey on deep learning in medical image registration: new technologies, uncertainty, evaluation metrics, and beyondcited by 55
  7. 20233DGR-CT: Sparse-View CT Reconstruction with a 3D Gaussian Representationcited by 25
  8. 2019Extreme MRI: Large-Scale Volumetric Dynamic Imaging from Continuous Non-Gated Acquisitionscited by 12
  9. 2020Non-rigid 3D motion estimation at high temporal resolution from prospectively undersampled k-space data using low-rank MR-MOTUScited by 3
  10. 2021Real-time non-rigid 3D respiratory motion estimation for MR-guided radiotherapy using MR-MOTUScited by 3
  11. 2025Time-resolved dynamic CBCT reconstruction using prior-model-free spatiotemporal Gaussian representation (PMF-STGR)cited by 2
  12. 2025MoRe-3DGSMR: Motion-resolved reconstruction framework for free-breathing pulmonary MRI based on 3D Gaussian representationcited by 1