Real-time non-rigid 3D respiratory motion estimation for MR-guided radiotherapy using MR-MOTUS
Not on the map. Why?
Abstract (arXiv)
The MR-Linac is a combination of an MR-scanner and radiotherapy linear accelerator (Linac) which holds the promise to increase the precision of radiotherapy treatments with MR-guided radiotherapy by monitoring motion during radiotherapy with MRI, and adjusting the radiotherapy plan accordingly. Optimal MR-guidance for respiratory motion during radiotherapy requires MR-based 3D motion estimation with a latency of 200-500 ms. Currently this is still challenging since typical methods rely on MR-images, and are therefore limited by the 3D MR-imaging latency. In this work, we present a method to perform non-rigid 3D respiratory motion estimation with 170 ms latency, including both acquisition and reconstruction. The proposed method called real-time low-rank MR-MOTUS reconstructs motion-fields directly from k-space data, and leverages an explicit low-rank decomposition of motion-fields to split the large scale 3D+t motion-field reconstruction problem posed in our previous work into two parts: (I) a medium-scale offline preparation phase and (II) a small-scale online inference phase which exploits the results of the offline phase for real-time computations. The method was validated on free-breathing data of five volunteers, acquired with a 1.5T Elekta Unity MR-Linac. Results show that the reconstructed 3D motion-field are anatomically plausible, highly correlated with a self-navigation motion surrogate (R = 0.975 +/- 0.0110), and can be reconstructed with a total latency of 170 ms that is sufficient for real-time MR-guided abdominal radiotherapy.
Key facts. Cited by 3 papers in the map (data through 7 Oct 2026). First posted on arXiv 16 Apr 2021.
Builds on
No reference list yet.
Built on by
Citing papers per year: 2024: 1; 2025: 0; 2026: 2.
3 papers.
- 2026Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)cited by 1
- 2024Highly efficient non-rigid registration in k-space with application to cardiac Magnetic Resonance Imagingcited by 0
- 2026Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolationcited by 0
- 2026Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation25 Aug 2026
- 2026Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)7 Apr 2026
- 2024Highly efficient non-rigid registration in k-space with application to cardiac Magnetic Resonance Imaging24 Oct 2024