DosimeTron: Automating Personalized Monte Carlo Radiation Dosimetry in PET/CT with Agentic AI
Not on the map. Why?
Abstract (arXiv)
Purpose: To develop and evaluate DosimeTron, an agentic AI system for automated patient-specific MC internal radiation dosimetry in PET/CT examinations. Materials and Methods: In this retrospective study, DosimeTron was evaluated on a publicly available PSMA-PET/CT dataset comprising 597 studies from 378 male patients acquired on three scanner models (18-F, n = 369; 68-Ga, n = 228). The system uses GPT-5.2 as its reasoning engine and 23 tools exposed via four Model Context Protocol servers, automating DICOM metadata extraction, image preprocessing, MC simulation, organ segmentation, and dosimetric reporting through natural-language interaction. Agentic performance was assessed using diverse prompt templates spanning single-turn instructions of varying specificity and multi-turn conversational exchanges, monitored via OpenTelemetry traces. Dosimetric accuracy was validated against OpenDose3D across 114 cases and 22 organs using Pearson's r, Lin's concordance correlation coefficient (CCC), and Bland-Altman analysis. Results: Across all prompt templates and all runs, no execution failures, pipeline errors, or hallucinated outputs were observed. Pearson's r ranged from 0.965 to 1.000 (median 0.997; all p < 0.001) and CCC from 0.963 to 1.000 (median 0.996). Mean absolute percentage difference was below 5% for 19 of 22 organs (median 2.5%). Total per-study processing time (SD) was 32.3 (6.0) minutes. Conclusion: DosimeTron autonomously executed complex dosimetry pipelines across diverse prompt configurations and achieved high dosimetric agreement with OpenDose3D at clinically acceptable processing times, demonstrating the feasibility of agentic AI for patient-specific Monte Carlo dosimetry in PET/CT.
Key facts. Cited by 1 paper in the map (data through 14 Oct 2026). Builds on 0 of its 12 references that are in the map. First posted on arXiv 7 Apr 2026.
Builds on
0 of 12 references.
No references here yet.
Built on by
Citing papers per year: 2026: 1.
1 paper.
Similar, not cited
Close in wording, no citation either way
- 2025Patient-specific AI for generation of 3D dosimetry imaging from two 2D-planar measurements
- 2025mAIstro: an open-source multi-agentic system for automated end-to-end development of radiomics and deep learning models for medical imaging
- 2025Scan-do Attitude: Towards Autonomous CT Protocol Management using a Large Language Model Agent
- 2025Automated stereotactic radiosurgery planning using a human-in-the-loop reasoning large language model agent
- 2026RadOnc-Agent: An LLM-Orchestrated Framework for AI Workflows Across the Radiotherapy Care Pathway
- 2025Agentic Systems in Radiology: Design, Applications, Evaluation, and Challenges
- 2026Agentic Autoresearch for CT Reconstruction
- 2026Agentic Large Language Models for Training-Free Neuro-Radiological Image Analysis