mlsanityData to 7 Oct 2026

Monocular Markerless Motion Capture Enables Quantitative Assessment of Upper Extremity Reachable Workspace

arXiv 2602.13176 ↗First posted 13 Feb 2026cs.CVcited by 1

Not on the map. Why?

Abstract (arXiv)

To validate a clinically accessible approach for quantifying the Upper Extremity Reachable Workspace (UERW) using a single (monocular) camera and Artificial Intelligence (AI)-driven Markerless Motion Capture (MMC) for biomechanical analysis. Objective assessment and validation of these techniques for specific clinically oriented tasks are crucial for their adoption in clinical motion analysis. AI-driven monocular MMC reduces the barriers to adoption in the clinic and has the potential to reduce the overhead for analysis of this common clinical assessment. Nine adult participants with no impairments performed the standardized UERW task, which entails reaching targets distributed across a virtual sphere centered on the torso, with targets displayed in a VR headset. Movements were simultaneously captured using a marker-based motion capture system and a set of eight FLIR cameras. We performed monocular video analysis on two of these video camera views to compare a frontal and offset camera configurations. The frontal camera orientation demonstrated strong agreement with the marker-based reference, exhibiting a minimal mean bias of 0.61 ± 0.12 % reachspace reached per octanct (mean ± standard deviation). In contrast, the offset camera view underestimated the percent workspace reached (-5.66 ± 0.45 % reachspace reached). Conclusion: The findings support the feasibility of a frontal monocular camera configuration for UERW assessment, particularly for anterior workspace evaluation where agreement with marker-based motion capture was highest. The overall performance demonstrates clinical potential for practical, single-camera assessments. This study provides the first validation of monocular MMC system for the assessment of the UERW task. By reducing technical complexity, this approach enables broader implementation of quantitative upper extremity mobility assessment.

Key facts. Cited by 1 paper in the map (data through 7 Oct 2026). Builds on 11 of its 54 references that are in the map. First posted on arXiv 13 Feb 2026.

Builds on

11 of 54 references.

References · 11

  1. 2017Attention Is All You Needcited by 59,932
  2. 2019MMDetection: Open MMLab Detection Toolbox and Benchmarkcited by 1,379
  3. 2021Equinox: neural networks in JAX via callable PyTrees and filtered transformationscited by 143
  4. 2020MoVi: A Large Multipurpose Motion and Video Datasetcited by 58
  5. 2020MeTRAbs: Metric-Scale Truncation-Robust Heatmaps for Absolute 3D Human Pose Estimationcited by 35
  6. 2024Differentiable Biomechanics Unlocks Opportunities for Markerless Motion Capturecited by 18
  7. 2025BioPose: Biomechanically-accurate 3D Pose Estimation from Monocular Videoscited by 16
  8. 2022Transforming Gait: Video-Based Spatiotemporal Gait Analysiscited by 8
  9. 2024Differentiable Biomechanics for Markerless Motion Capture in Upper Limb Stroke Rehabilitation: A Comparison with Optical Motion Capturecited by 8
  10. 2025Portable Biomechanics Laboratory: Clinically Accessible Movement Analysis from a Handheld Smartphonecited by 8
  11. 2024Platypose: Calibrated Zero-Shot Multi-Hypothesis 3D Human Motion Estimationcited by 2

Built on by

Cited by year (2026 to 7 Oct)

Citing papers per year: 2026: 1.

1 paper.