R2MF-Net: A Recurrent Residual Multi-Path Fusion Network for Robust Multi-directional Spine X-ray Segmentation
Not on the map. Why?
Abstract (arXiv)
Accurate segmentation of spinal structures in X-ray images is a prerequisite for quantitative scoliosis assessment, including Cobb angle measurement, vertebral translation estimation and curvature classification. In routine practice, clinicians acquire coronal, left-bending and right-bending radiographs to jointly evaluate deformity severity and spinal flexibility. However, the segmentation step remains heavily manual, time-consuming and non-reproducible, particularly in low-contrast images and in the presence of rib shadows or overlapping tissues. To address these limitations, this paper proposes R2MF-Net, a recurrent residual multi-path encoder--decoder network tailored for automatic segmentation of multi-directional spine X-ray images. The overall design consists of a coarse segmentation network and a fine segmentation network connected in cascade. Both stages adopt an improved Inception-style multi-branch feature extractor, while a recurrent residual jump connection (R2-Jump) module is inserted into skip paths to gradually align encoder and decoder semantics. A multi-scale cross-stage skip (MC-Skip) mechanism allows the fine network to reuse hierarchical representations from multiple decoder levels of the coarse network, thereby strengthening the stability of segmentation across imaging directions and contrast conditions. Furthermore, a lightweight spatial-channel squeeze-and-excitation block (SCSE-Lite) is employed at the bottleneck to emphasize spine-related activations and suppress irrelevant structures and background noise. We evaluate R2MF-Net on a clinical multi-view radiograph dataset comprising 228 sets of coronal, left-bending and right-bending spine X-ray images with expert annotations.
Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 16 of its 26 references that are in the map. First posted on arXiv 8 Dec 2025.
Builds on
16 of 26 references.
References · 16
- 2015Deep Residual Learning for Image Recognitioncited by 51,809
- 2015U-Net: Convolutional Networks for Biomedical Image Segmentationcited by 19,604
- 2016Densely Connected Convolutional Networkscited by 6,691
- 2014Fully Convolutional Networks for Semantic Segmentationcited by 4,845
- 2017Squeeze-and-Excitation Networkscited by 4,763
- 2018Encoder-Decoder with Atrous Separable Convolution for Semantic Image Segmentationcited by 3,210
- 2016V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentationcited by 2,284
- 2021TransUNet: Transformers Make Strong Encoders for Medical Image Segmentationcited by 1,552
- 20163D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotationcited by 1,471
- 2018Attention U-Net: Learning Where to Look for the Pancreascited by 1,420
- 2022Swin UNETR: Swin Transformers for Semantic Segmentation of Brain Tumors in MRI Imagescited by 823
- 2020Image Segmentation Using Deep Learning: A Surveycited by 659
4 more
- 2016The Importance of Skip Connections in Biomedical Image Segmentationcited by 126
- 2018Concurrent Spatial and Channel Squeeze & Excitation in Fully Convolutional Networkscited by 120
- 2019HarDNet: A Low Memory Traffic Networkcited by 76
- 2017Fully Automatic Segmentation of Lumbar Vertebrae from CT Images using Cascaded 3D Fully Convolutional Networkscited by 11
Built on by
Not cited yet.