From Noise to Knowledge: A Comparative Study of Acoustic Anomaly Detection Models in Pumped-storage Hydropower Plants
Not on the map. Why?
Abstract (arXiv)
In the context of industrial factories and energy producers, unplanned outages are highly costly and difficult to service. However, existing acoustic-anomaly detection studies largely rely on generic industrial or synthetic datasets, with few focused on hydropower plants due to limited access. This paper presents a comparative analysis of acoustic-based anomaly detection methods, as a way to improve predictive maintenance in hydropower plants. We address key challenges in the acoustic preprocessing under highly noisy conditions before extracting time- and frequency-domain features. Then, we benchmark three machine learning models: LSTM AE, K-Means, and OC-SVM, which are tested on two real-world datasets from the Rodundwerk II pumped-storage plant in Austria, one with induced anomalies and one with real-world conditions. The One-Class SVM achieved the best trade-off of accuracy (ROC AUC 0.966-0.998) and minimal training time, while the LSTM autoencoder delivered strong detection (ROC AUC 0.889-0.997) at the expense of higher computational cost.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 1 of its 31 references that are in the map. First posted on arXiv 26 Sep 2025.
Builds on
1 of 31 references.
References · 1
Built on by
Not cited yet.