Reducing Overtreatment of Indeterminate Thyroid Nodules Using a Multimodal Deep Learning Model
Not on the map. Why?
Abstract (arXiv)
Objective: Molecular testing (MT) classifies cytologically indeterminate thyroid nodules as benign or malignant with high sensitivity but low positive predictive value (PPV), only using molecular profiles, ignoring ultrasound (US) imaging and biopsy. We address this limitation by applying attention multiple instance learning (AMIL) to US images. Methods: We retrospectively reviewed 333 patients with indeterminate thyroid nodules at UCLA medical center (259 benign, 74 malignant). A multi-modal deep learning AMIL model was developed, combining US images and MT to classify the nodules as benign or malignant and enhance the malignancy risk stratification of MT. Results: The final AMIL model matched MT sensitivity (0.946) while significantly improving PPV (0.477 vs 0.448 for MT alone), indicating fewer false positives while maintaining high sensitivity. Conclusion: Our approach reduces false positives compared to MT while maintaining the same ability to identify positive cases, potentially reducing unnecessary benign thyroid resections in patients with indeterminate nodules.
Key facts. No citing papers in the map yet (data through 14 Oct 2026). Builds on 4 of its 24 references that are in the map. First posted on arXiv 27 Sep 2024.
Builds on
4 of 24 references.
References · 4
- 2015Deep Residual Learning for Image Recognitioncited by 52,096
- 2018Attention-based Deep Multiple Instance Learningcited by 1,095
- 2017Deep Learning for Medical Image Analysiscited by 401
- 2019A Simple Dynamic Learning Rate Tuning Algorithm For Automated Training of DNNscited by 7
Built on by