Five Pitfalls When Assessing Synthetic Medical Images with Reference Metrics

arXiv 2408.06075 ↗First posted 12 Aug 2024eess.IV cs.CVcited by 4

Not on the map. Why?

Abstract (arXiv)

Reference metrics have been developed to objectively and quantitatively compare two images. Especially for evaluating the quality of reconstructed or compressed images, these metrics have shown very useful. Extensive tests of such metrics on benchmarks of artificially distorted natural images have revealed which metric best correlate with human perception of quality. Direct transfer of these metrics to the evaluation of generative models in medical imaging, however, can easily lead to pitfalls, because assumptions about image content, image data format and image interpretation are often very different. Also, the correlation of reference metrics and human perception of quality can vary strongly for different kinds of distortions and commonly used metrics, such as SSIM, PSNR and MAE are not the best choice for all situations. We selected five pitfalls that showcase unexpected and probably undesired reference metric scores and discuss strategies to avoid them.

Key facts. Cited by 4 papers in the map (data through 14 Oct 2026). Builds on 4 of its 21 references that are in the map. First posted on arXiv 12 Aug 2024.

Builds on

4 of 21 references.

References · 4

  1. 2023Understanding metric-related pitfalls in image analysis validationcited by 58
  2. 2023The Brain Tumor Segmentation (BraTS) Challenge 2023: Brain MR Image Synthesis for Tumor Segmentation (BraSyn)cited by 24
  3. 2024Similarity and Quality Metrics for MR Image-To-Image Translationcited by 20
  4. 2020Comparison of Image Quality Models for Optimization of Image Processing Systemscited by 8

Built on by

Cited by year (2026 to 14 Oct)

Citing papers per year: 2025: 3; 2026: 1.

4 papers.