mlsanityData to 7 Oct 2026

Thyroidiomics: An Automated Pipeline for Segmentation and Classification of Thyroid Pathologies from Scintigraphy Images

arXiv 2407.10336 ↗First posted 14 Jul 2024eess.IV cs.CV cs.LGcited by 0

Not on the map. Why?

Abstract (arXiv)

The objective of this study was to develop an automated pipeline that enhances thyroid disease classification using thyroid scintigraphy images, aiming to decrease assessment time and increase diagnostic accuracy. Anterior thyroid scintigraphy images from 2,643 patients were collected and categorized into diffuse goiter (DG), multinodal goiter (MNG), and thyroiditis (TH) based on clinical reports, and then segmented by an expert. A ResUNet model was trained to perform auto-segmentation. Radiomic features were extracted from both physician (scenario 1) and ResUNet segmentations (scenario 2), followed by omitting highly correlated features using Spearman's correlation, and feature selection using Recursive Feature Elimination (RFE) with XGBoost as the core. All models were trained under leave-one-center-out cross-validation (LOCOCV) scheme, where nine instances of algorithms were iteratively trained and validated on data from eight centers and tested on the ninth for both scenarios separately. Segmentation performance was assessed using the Dice similarity coefficient (DSC), while classification performance was assessed using metrics, such as precision, recall, F1-score, accuracy, area under the Receiver Operating Characteristic (ROC AUC), and area under the precision-recall curve (PRC AUC). ResUNet achieved DSC values of 0.84±0.03, 0.71±0.06, and 0.86±0.02 for MNG, TH, and DG, respectively. Classification in scenario 1 achieved an accuracy of 0.76±0.04 and a ROC AUC of 0.92±0.02 while in scenario 2, classification yielded an accuracy of 0.74±0.05 and a ROC AUC of 0.90±0.02. The automated pipeline demonstrated comparable performance to physician segmentations on several classification metrics across different classes, effectively reducing assessment time while maintaining high diagnostic accuracy. Code available at: https://github.com/ahxmeds/thyroidiomics.git.

Key facts. No citing papers in the map yet (data through 7 Oct 2026). Builds on 3 of its 25 references that are in the map. First posted on arXiv 14 Jul 2024.

Builds on

3 of 25 references.

References · 3

  1. 2022MONAI: An open-source framework for deep learning in healthcarecited by 438
  2. 2020Metrics for Multi-Class Classification: an Overviewcited by 140
  3. 2022Segmentation and Risk Score Prediction of Head and Neck Cancers in PET/CT Volumes with 3D U-Net and Cox Proportional Hazard Neural Networkscited by 2

Built on by

Not cited yet.