mlsanityData to 7 Oct 2026

Image2Flow: A hybrid image and graph convolutional neural network for rapid patient-specific pulmonary artery segmentation and CFD flow field calculation from 3D cardiac MRI data

arXiv 2402.18236 ↗First posted 28 Feb 2024cs.CVcited by 1

Not on the map. Why?

Abstract (arXiv)

Computational fluid dynamics (CFD) can be used for evaluation of hemodynamics. However, its routine use is limited by labor-intensive manual segmentation, CFD mesh creation, and time-consuming simulation. This study aims to train a deep learning model to both generate patient-specific volume-meshes of the pulmonary artery from 3D cardiac MRI data and directly estimate CFD flow fields. This study used 135 3D cardiac MRIs from both a public and private dataset. The pulmonary arteries in the MRIs were manually segmented and converted into volume-meshes. CFD simulations were performed on ground truth meshes and interpolated onto point-point correspondent meshes to create the ground truth dataset. The dataset was split 85/10/15 for training, validation and testing. Image2Flow, a hybrid image and graph convolutional neural network, was trained to transform a pulmonary artery template to patient-specific anatomy and CFD values. Image2Flow was evaluated in terms of segmentation and accuracy of CFD predicted was assessed using node-wise comparisons. Centerline comparisons of Image2Flow and CFD simulations performed using machine learning segmentation were also performed. Image2Flow achieved excellent segmentation accuracy with a median Dice score of 0.9 (IQR: 0.86-0.92). The median node-wise normalized absolute error for pressure and velocity magnitude was 11.98% (IQR: 9.44-17.90%) and 8.06% (IQR: 7.54-10.41), respectively. Centerline analysis showed no significant difference between the Image2Flow and conventional CFD simulated on machine learning-generated volume-meshes. This proof-of-concept study has shown it is possible to simultaneously perform patient specific volume-mesh based segmentation and pressure and flow field estimation. Image2Flow completes segmentation and CFD in ~205ms, which ~7000 times faster than manual methods, making it more feasible in a clinical environment.

Key facts. Cited by 1 paper in the map (data through 7 Oct 2026). Builds on 10 of its 34 references that are in the map. First posted on arXiv 28 Feb 2024.

Builds on

10 of 34 references.

References · 10

  1. 2019Deep learning for cardiac image segmentation: A reviewcited by 131
  2. 2019Evaluation of Algorithms for Multi-Modality Whole Heart Segmentation: An Open-Access Grand Challengecited by 100
  3. 2020Graph Neural Networks in TensorFlow and Keras with Spektralcited by 59
  4. 2019Voxel2Mesh: 3D Mesh Model Generation from Volumetric Datacited by 52
  5. 2021A Deep-Learning Approach For Direct Whole-Heart Mesh Reconstructioncited by 47
  6. 2022Learning Whole Heart Mesh Generation From Patient Images For Computational Simulationscited by 21
  7. 2023Learning Reduced-Order Models for Cardiovascular Simulations with Graph Neural Networkscited by 20
  8. 2023SDF4CHD: Generative Modeling of Cardiac Anatomies with Congenital Heart Defectscited by 17
  9. 2021Whole Heart Mesh Generation For Image-Based Computational Simulations By Learning Free-From Deformationscited by 12
  10. 2022Deep neural networks for fast acquisition of aortic 3D pressure and velocity flow fieldscited by 2

Built on by

Cited by year

Citing papers per year: 2025: 1.

1 paper.