ProtoASNet: Dynamic Prototypes for Inherently Interpretable and Uncertainty-Aware Aortic Stenosis Classification in Echocardiography
Not on the map. Why?
Abstract (arXiv)
Aortic stenosis (AS) is a common heart valve disease that requires accurate and timely diagnosis for appropriate treatment. Most current automatic AS severity detection methods rely on black-box models with a low level of trustworthiness, which hinders clinical adoption. To address this issue, we propose ProtoASNet, a prototypical network that directly detects AS from B-mode echocardiography videos, while making interpretable predictions based on the similarity between the input and learned spatio-temporal prototypes. This approach provides supporting evidence that is clinically relevant, as the prototypes typically highlight markers such as calcification and restricted movement of aortic valve leaflets. Moreover, ProtoASNet utilizes abstention loss to estimate aleatoric uncertainty by defining a set of prototypes that capture ambiguity and insufficient information in the observed data. This provides a reliable system that can detect and explain when it may fail. We evaluate ProtoASNet on a private dataset and the publicly available TMED-2 dataset, where it outperforms existing state-of-the-art methods with an accuracy of 80.0% and 79.7%, respectively. Furthermore, ProtoASNet provides interpretability and an uncertainty measure for each prediction, which can improve transparency and facilitate the interactive usage of deep networks to aid clinical decision-making. Our source code is available at: https://github.com/hooman007/ProtoASNet.
Key facts. Cited by 11 papers in the map (data through 7 Oct 2026). Builds on 12 of its 23 references that are in the map. First posted on arXiv 26 Jul 2023.
Builds on
12 of 23 references.
References · 12
- 2016Grad-CAM: Visual Explanations from Deep Networks via Gradient-based Localizationcited by 6,690
- 2013Deep Inside Convolutional Networks: Visualising Image Classification Models and Saliency Mapscited by 2,348
- 2018Sanity Checks for Saliency Mapscited by 1,149
- 2017A Closer Look at Spatiotemporal Convolutions for Action Recognitioncited by 1,139
- 2018This Looks Like That: Deep Learning for Interpretable Image Recognitioncited by 731
- 2018Learning Confidence for Out-of-Distribution Detection in Neural Networkscited by 245
- 2020Interpretable and Accurate Fine-grained Recognition via Region Groupingcited by 75
- 2021XProtoNet: Diagnosis in Chest Radiography with Global and Local Explanationscited by 72
- 2021A New Semi-supervised Learning Benchmark for Classifying View and Diagnosing Aortic Stenosis from Echocardiogramscited by 15
- 2019On Modelling Label Uncertainty in Deep Neural Networks: Automatic Estimation of Intra-observer Variability in 2D Echocardiography Quality Assessmentcited by 12
- 2022INSightR-Net: Interpretable Neural Network for Regression using Similarity-based Comparisons to Prototypical Examplescited by 8
- 2023Hierarchical Explanations for Video Action Recognitioncited by 5
Built on by
Citing papers per year: 2024: 3; 2025: 3; 2026: 5.
11 papers.
- 2025Uncertainty Quantification for Machine Learning in Healthcare: A Surveycited by 11
- 2024Semi-Supervised Multimodal Multi-Instance Learning for Aortic Stenosis Diagnosiscited by 4
- 2024Reliable Multi-View Learning with Conformal Prediction for Aortic Stenosis Classification in Echocardiographycited by 3
- 2024ProtoAL: Interpretable Deep Active Learning with prototypes for medical imagingcited by 2
- 2025PRECISE-AS: Personalized Reinforcement Learning for Efficient Point-of-Care Echocardiography in Aortic Stenosis Diagnosiscited by 2
- 2025ProtoEFNet: Dynamic Prototype Learning for Inherently Interpretable Ejection Fraction Estimation in Echocardiographycited by 2
- 2026Concerning Uncertainty -- A Systematic Survey of Uncertainty-Aware XAIcited by 2
- 2026Optimizing Point-of-Care Ultrasound Video Acquisition for Probabilistic Multi-Task Heart Failure Detectioncited by 0
- 2026ProtoTTA: Prototype-Guided Test-Time Adaptationcited by 0
- 2026HypOProto: Hyperbolic Ordinal Prototypes for Left Ventricular Filling Pressure Classificationcited by 0
- 2026ProtoPointNet: Prototype-Based Interpretable Classification of 3D Dental Point Clouds with Verifiable Spatial Activationscited by 0
- 2026ProtoPointNet: Prototype-Based Interpretable Classification of 3D Dental Point Clouds with Verifiable Spatial Activations14 Jul 2026
- 2026HypOProto: Hyperbolic Ordinal Prototypes for Left Ventricular Filling Pressure Classification18 Jun 2026
- 2026ProtoTTA: Prototype-Guided Test-Time Adaptation16 Apr 2026
- 2026Concerning Uncertainty -- A Systematic Survey of Uncertainty-Aware XAI27 Mar 2026
- 2026Optimizing Point-of-Care Ultrasound Video Acquisition for Probabilistic Multi-Task Heart Failure Detection14 Feb 2026
- 2025ProtoEFNet: Dynamic Prototype Learning for Inherently Interpretable Ejection Fraction Estimation in Echocardiography3 Dec 2025
- 2025PRECISE-AS: Personalized Reinforcement Learning for Efficient Point-of-Care Echocardiography in Aortic Stenosis Diagnosis2 Sep 2025
- 2025Uncertainty Quantification for Machine Learning in Healthcare: A Survey4 May 2025
- 2024Reliable Multi-View Learning with Conformal Prediction for Aortic Stenosis Classification in Echocardiography15 Sep 2024
- 2024ProtoAL: Interpretable Deep Active Learning with prototypes for medical imaging6 Apr 2024
- 2024Semi-Supervised Multimodal Multi-Instance Learning for Aortic Stenosis Diagnosis9 Mar 2024