mlsanityData to 14 Oct 2026

Unsupervised sequence-to-sequence learning for automatic signal quality assessment in multi-channel electrical impedance-based hemodynamic monitoring

arXiv 2305.09368 ↗First posted 16 May 2023eess.SP cs.AI physics.med-phcited by 2

Not on the map. Why?

Abstract (arXiv)

This study proposes an unsupervised sequence-to-sequence learning approach that automatically assesses the motion-induced reliability degradation of the cardiac volume signal (CVS) in multi-channel electrical impedance-based hemodynamic monitoring. The proposed method attempts to tackle shortcomings in existing learning-based assessment approaches, such as the requirement of manual annotation for motion influence and the lack of explicit mechanisms for realizing motion-induced abnormalities under contextual variations in CVS over time. By utilizing long-short term memory and variational auto-encoder structures, an encoder--decoder model is trained not only to self-reproduce an input sequence of the CVS but also to extrapolate the future in a parallel fashion. By doing so, the model can capture contextual knowledge lying in a temporal CVS sequence while being regularized to explore a general relationship over the entire time-series. A motion-influenced CVS of low-quality is detected, based on the residual between the input sequence and its neural representation with a cut--off value determined from the two-sigma rule of thumb over the training set. Our experimental observations validated two claims: (i) in the learning environment of label-absence, assessment performance is achievable at a competitive level to the supervised setting, and (ii) the contextual information across a time series of CVS is advantageous for effectively realizing motion-induced unrealistic distortions in signal amplitude and morphology. We also investigated the capability as a pseudo-labeling tool to minimize human-craft annotation by preemptively providing strong candidates for motion-induced anomalies. Empirical evidence has shown that machine-guided annotation can reduce inevitable human-errors during manual assessment while minimizing cumbersome and time-consuming processes.

Key facts. Cited by 2 papers in the map (data through 14 Oct 2026). Builds on 6 of its 48 references that are in the map. First posted on arXiv 16 May 2023.

Builds on

6 of 48 references.

References · 6

  1. 2019PyTorch: An Imperative Style, High-Performance Deep Learning Librarycited by 20,305
  2. 2013Auto-Encoding Variational Bayescited by 4,053
  3. 2021Reference-guided Pseudo-Label Generation for Medical Semantic Segmentationcited by 33
  4. 2020Deep Learning-Based Solvability of Underdetermined Inverse Problems in Medical Imagingcited by 14
  5. 2019Framelet Pooling Aided Deep Learning Network : The Method to Process High Dimensional Medical Datacited by 3
  6. 2023Machine Learning-based Signal Quality Assessment for Cardiac Volume Monitoring in Electrical Impedance Tomographycited by 1

Built on by

Cited by year

Citing papers per year: 2024: 2.